arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2604.00205cs.LG
收藏

无监督4D流体磁共振成像速度增强与解缠绕使用无散度神经网络

Unsupervised 4D Flow MRI Velocity Enhancement and Unwrapping Using Divergence-Free Neural Networks

Biomedical Imaging Center, Pontificia Universidad Católica de Chile (PUC)(智利天主教大学生物医学成像中心);Department of Electrical Engineering, PUC(智利天主教大学电气工程系);Millennium Institute for Intelligent Healthcare Engineering, iHEALTH(千年智能医疗工程研究所);Departamento de Informática, Universidad Técnica Federico Santa Maria(费德里科·圣玛丽亚技术大学计算机科学系);School of Electrical Engineering, Pontificia Universidad Católica de Valparaiso (PUCV)(智利瓦尔帕莱索天主教大学电气工程学院);Center for Interdisciplinary Research in Biomedicine, Biotechnology and Well-Being (CID3B), PUCV(智利瓦尔帕莱索天主教大学生物医学、生物技术与福祉跨学科研究中心);Departamento de Ingeniería Mecánica, Universidad Técnica Federico Santa Maria(费德里科·圣玛丽亚技术大学机械工程系);Karolinska Institute, Department of Molecular Medicine and Surgery(卡罗林斯卡学院分子医学与外科学系)

Javier Bisbal, Julio Sotelo, Hernán Mella, Oliver Welin Odeback, Joaquín Mura, David Marlevi, Junya Matsuda, Kotomi Iwata, Tetsuro Sekine, Cristian Tejos, Sergio Uribe

AI总结:

本文提出了一种无监督的无散度和混叠自由神经网络(DAF-FlowNet),用于4D流体磁共振成像,同时增强噪声速度场并纠正相位缠绕伪影。

摘要:

本文介绍了一种无监督的无散度和混叠自由神经网络(DAF-FlowNet),用于4D流体磁共振成像,该网络联合增强噪声速度场并纠正相位缠绕伪影。DAF-FlowNet将速度参数化为矢量势的旋度,通过构造保证质量守恒,避免显式散度惩罚调优。余弦数据一致性损失使网络能够同时从缠绕相位图像中去噪和解缠绕。在由计算流体动力学生成的合成主动脉4D流体磁共振成像中,DAF-FlowNet在噪声水平下实现了比现有技术更低的误差(速度归一化均方根误差低至11%,方向误差低11%,散度低44%),并且对中等分割扰动具有鲁棒性。在峰值速度/速度编码比为1.4和2.1时,DAF-FlowNet实现了0.18%和5.2%的剩余缠绕体素,分别比最佳替代方法减少了72%和18%。在存在噪声和混叠的情况下,所提出的单阶段方法优于最先进的顺序流程(速度归一化均方根误差低15%,方向误差低11%,散度低28%)。在10个肥厚型心肌病患者数据集中,DAF-FlowNet保留了细尺度流体特征,纠正了混叠区域,并提高了内部流体一致性,如主动脉和肺部质量守恒分析中减少的平面间流体偏倚所示,这些分析由4D流体磁共振成像共识指南推荐。这些结果支持DAF-FlowNet作为一种统一速度增强和相位解缠绕的框架,以提高心血管4D流体磁共振成像的可靠性。

英文摘要:

This work introduces an unsupervised Divergence and Aliasing-Free neural network (DAF-FlowNet) for 4D Flow Magnetic Resonance Imaging (4D Flow MRI) that jointly enhances noisy velocity fields and corrects phase wrapping artifacts. DAF-FlowNet parameterizes velocities as the curl of a vector potential, enforcing mass conservation by construction and avoiding explicit divergence-penalty tuning. A cosine data-consistency loss enables simultaneous denoising and unwrapping from wrapped phase images. On synthetic aortic 4D Flow MRI generated from computational fluid dynamics, DAF-FlowNet achieved lower errors than existing techniques (up to 11% lower velocity normalized root mean square error, 11% lower directional error, and 44% lower divergence relative to the best-performing alternative across noise levels), with robustness to moderate segmentation perturbations. For unwrapping, at peak velocity/velocity-encoding ratios of 1.4 and 2.1, DAF-FlowNet achieved 0.18% and 5.2% residual wrapped voxels, representing reductions of 72% and 18% relative to the best alternative method, respectively. In scenarios with both noise and aliasing, the proposed single-stage formulation outperformed a state-of-the-art sequential pipeline (up to 15% lower velocity normalized root mean square error, 11% lower directional error, and 28% lower divergence). Across 10 hypertrophic cardiomyopathy patient datasets, DAF-FlowNet preserved fine-scale flow features, corrected aliased regions, and improved internal flow consistency, as indicated by reduced inter-plane flow bias in aortic and pulmonary mass-conservation analyses recommended by the 4D Flow MRI consensus guidelines. These results support DAF-FlowNet as a framework that unifies velocity enhancement and phase unwrapping to improve the reliability of cardiovascular 4D Flow MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑