arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2604.00175cs.LGcs.CV
收藏

利用智能Lacelock传感器进行站起过渡检测与持续时间测量

Sit-to-Stand Transitions Detection and Duration Measurement Using Smart Lacelock Sensor

The University of Alabama(阿拉巴马大学);Genesis Medtech USA Inc(Genesis Medtech 美国公司);Whitworth University(惠特沃斯大学)

Md Rafi Islam, Md Rejwanul Haque, Elizabeth Choma, Shannon Hayes, Siobhan McMahon, Xiangrong Shen, Edward Sazonov

AI总结:

本文提出利用智能Lacelock传感器检测站起过渡及测量持续时间的方法,通过多模态信号特征训练四个分类器,实现高准确率的检测与测量,为老年人跌倒风险评估提供新工具。

摘要:

运动中的姿势稳定性对独立生活、防跌倒和整体健康至关重要,尤其是老年人因年龄相关因素导致的平衡、肌肉力量和活动能力下降。在日常功能活动中,站起过渡(SiSt)是下肢力量、骨骼肌肉健康和跌倒风险的关键指标,是评估功能能力和监测老年人身体衰退的重要参数。本文提出了一种利用智能Lacelock传感器进行SiSt过渡检测和持续时间测量的方法,该传感器是一种轻量化的鞋-mounted设备,集成了力传感器、加速度计和陀螺仪用于运动分析。该方法在16名老年人(平均年龄76.84岁,标准差3.45岁)中进行了评估,他们在Short Physical Performance Battery(SPPB)协议下执行SiSt任务。从多模态信号中提取的特征用于训练和评估四个机器学习分类器,使用四折参与者独立交叉验证来分类SiSt过渡并测量其持续时间。袋ged树分类器在分类SiSt过渡时的准确率为0.98,F1得分为0.8。正确分类的过渡持续时间的平均绝对误差为0.047秒,标准差为0.07秒。这些发现突显了智能Lacelock传感器在老年人跌倒风险评估和运动监测中的潜力。

英文摘要:

Postural stability during movement is fundamental to independent living, fall prevention, and overall health, particularly among older adults who experience age-related declines in balance, muscle strength, and mobility. Among daily functional activities, the Sit-to-Stand (SiSt) transition is a critical indicator of lower-limb strength, musculoskeletal health, and fall risk, making it an essential parameter for assessing functional capacity and monitoring physical decline in aging populations. This study presents a methodology SiSt transition detection and duration measurement using the Smart Lacelock sensor, a lightweight, shoe-mounted device that integrates a load cell, accelerometer, and gyroscope for motion analysis. The methodology was evaluated in 16 older adults (age: mean: 76.84, SD: 3.45 years) performing SiSt tasks within the Short Physical Performance Battery (SPPB) protocol. Features extracted from multimodal signals were used to train and evaluate four machine learning classifiers using a 4-fold participant-independent cross-validation to classify SiSt transitions and measure their duration. The bagged tree classifier achieved an accuracy of 0.98 and an F1 score of 0.8 in classifying SiSt transition. The mean absolute error in duration measurement of the correctly classified transitions was 0.047, and the SD was 0.07 seconds. These findings highlight the potential of the Smart Lacelock sensor for real-world fall-risk assessment and mobility monitoring in older adults.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑