通过结构正交初始化实现位相同的医学深度学习
Bit-Identical Medical Deep Learning via Structured Orthogonal Initialization
AI总结:
本文提出一种验证位相同训练的框架,通过消除权重初始化、批次顺序和非确定性GPU操作的随机性,减少模型输出的方差,验证了结构正交初始化在ECG分类和跨领域任务中的有效性。
摘要:
深度学习训练是非确定性的:相同代码使用不同随机种子会产生在聚合指标上一致但在个体预测上不同的模型,稀有临床类别上的每类AUC波动超过20个百分点。我们提出了一种验证位相同训练的框架,消除了三个随机性来源:权重初始化(通过结构化正交基函数)、批次顺序(通过黄金比例调度)和非确定性GPU操作(通过架构选择和定制autograd)。该流程在独立运行中产生MD5验证的相同训练权重。在PTB-XL ECG节律分类中,结构化初始化在两个架构中显著优于Kaiming(n=20;Conformer p=0.016,Baseline p<0.001),减少了聚合方差2-3倍,并在稀有节律上减少了多达7.5倍的方差(TRIGU范围:4.1pp vs 30.9pp在Kaiming下,独立验证由3折交叉验证确认)。在n=20的四基比较中,所有结构化正交基产生等效性能(Friedman p=0.48),证明了贡献是确定性的结构化初始化本身,而非特定基函数。在七个MedMNIST基准上的跨领域验证(n=20,所有p>0.14)确认了在标准任务中无性能惩罚;在不平衡任务(ChestMNIST、RetinaMNIST)上的每类分析显示,在ECG中观察到的稀有类方差减少相同。在三个外部ECG数据库上的跨数据集评估确认了零样本泛化(>0.93 AFIB AUC)。
英文摘要:
Deep learning training is non-deterministic: identical code with different random seeds produces models that agree on aggregate metrics but disagree on individual predictions, with per-class AUC swings exceeding 20 percentage points on rare clinical classes. We present a framework for verified bit-identical training that eliminates three sources of randomness: weight initialization (via structured orthogonal basis functions), batch ordering (via golden ratio scheduling), and non-deterministic GPU operations (via architecture selection and custom autograd). The pipeline produces MD5-verified identical trained weights across independent runs. On PTB-XL ECG rhythm classification, structured initialization significantly exceeds Kaiming across two architectures (n=20; Conformer p = 0.016, Baseline p < 0.001), reducing aggregate variance by 2-3x and reducing per-class variability on rare rhythms by up to 7.5x (TRIGU range: 4.1pp vs 30.9pp under Kaiming, independently confirmed by 3-fold CV). A four-basis comparison at n=20 shows all structured orthogonal bases produce equivalent performance (Friedman p=0.48), establishing that the contribution is deterministic structured initialization itself, not any particular basis function. Cross-domain validation on seven MedMNIST benchmarks (n=20, all p > 0.14) confirms no performance penalty on standard tasks; per-class analysis on imbalanced tasks (ChestMNIST, RetinaMNIST) shows the same variance reduction on rare classes observed in ECG. Cross-dataset evaluation on three external ECG databases confirms zero-shot generalization (>0.93 AFIB AUC).
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。