arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.26483cs.LG
收藏

EcoFair:面向隐私保护垂直分区医疗推断的可信且节能路由

EcoFair: Energy-Efficient Inference Routing for Edge AI under Data Degradation

School of Digital and Physical Science, University of Hull(赫尔大学数字与物理科学学院)

Mostafa Anoosha, Dhavalkumar Thakker, Kuniko Paxton, Koorosh Aslansefat, Bhupesh Kumar Mishra, Baseer Ahmad, Rameez Raja Kureshi

AI总结:

EcoFair通过轻量级优先路由机制,在保持数据本地化的同时,减少边缘侧推断能耗,同时保持分类性能,提升高危病例的敏感性。

摘要:

隐私保护的医疗推断需平衡数据本地性、诊断可靠性与部署效率。本文提出EcoFair,一种模拟垂直分区推断框架,用于皮肤病诊断,在此框架中,原始图像和表格数据保持本地,仅传输模态特定嵌入用于服务器端多模态融合。EcoFair引入轻量级优先路由机制,当本地不确定性或元数据衍生的临床风险指示需要额外计算时,选择性激活更重的图像编码器。路由决策结合预测不确定性、安全-危险概率间隙以及从患者年龄和病变定位导出的表格神经符号风险分数。在三个皮肤病基准测试中,EcoFair显著减少边缘侧推断能耗,同时保持分类性能竞争力。结果进一步表明,选择性路由可在不修改全局训练目标的情况下,提升高危病例的敏感性。这些发现使EcoFair成为在边缘部署约束下,隐私保护和节能医疗推断的实用框架。

英文摘要:

Medical edge-AI systems must operate under a difficult tension: delivering reliable diagnostic inference while running on devices with limited battery capacity, memory, and compute. In dermatology, this problem is amplified by real-world image degradation caused by smartphone capture, poor lighting, blur, compression, and heterogeneous edge sensors. To handle these degraded inputs, deploying a heavyweight model can improve reliability, but it rapidly increases the energy burden on resource-constrained devices. Conversely, always using a lightweight model saves energy but may be less reliable on ambiguous or degraded inputs. This paper introduces EcoFair, a vertically partitioned inference framework for dermatology classification in which image and tabular inputs remain local to edge clients while only learned modality-specific representations are transmitted for server-side fusion. EcoFair first processes each sample using a lightweight image encoder and then decides whether additional heavyweight computation is necessary. Escalation is triggered when the lightweight prediction exhibits high uncertainty, a narrow separation between safe and high-risk classes, or elevated metadata-derived risk from patient age and lesion location. Across HAM10000, BCN20000, and PAD-UFES-20, EcoFair is evaluated using multiple lightweight--heavy backbone pairings to quantify the trade-off between energy consumption, diagnostic performance, and worst-group malignant-case recall. Results show that EcoFair can reduce per-sample image-inference energy by up to 68\% relative to always using the heavyweight encoder, while selectively allocating additional computation under difficult data regimes to support inference reliability. Group-level analysis further shows configuration-dependent effects, with improvements in selected model--dataset settings and mixed behaviour in others.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑