JanusBM:一种双保真多区白箱建筑建模框架
JanusBM: A Dual-Fidelity Multi-Zone White-Box Building Modeling Framework
AI总结:
本文提出JanusBM框架,结合高保真水力模型与低保真理想负载替代模型,通过双阶段验证校准流程实现多时间尺度的建筑能耗模拟,提升年度分析效率并满足瞬态峰值评估需求。
摘要:
准确的建筑能耗模型对分析耦合能源系统至关重要,其中建筑与电动供暖、储能和先进控制在各种场景中相互作用。高保真(HiFi)白箱模型能够解析水力分配和发射器动态,捕捉短期瞬变,但其数值刚性和计算负担限制了长期模拟和大规模场景探索。相反,降阶低保真(LoFi)表示能够快速进行年度评估,但可能无法捕捉水力和控制引起的动态,这些动态决定了瞬变和峰值行为。本文提出了一种双保真、多区白箱建筑建模框架,称为JanusBM,基于新型拓扑驱动建模工具RoomFlex6D,耦合HiFi水力模型和LoFi理想负载替代模型,该模型在Modelica中移除了显式水力状态。为确保在时间尺度上的适用性和物理一致性,我们引入了两阶段混合验证和校准流程,利用互补数据:IEA EBC Annex 60基准用于能源规模验证,以及来自现实世界实验建筑的时间序列测量用于水力动态规模校准。结果表明,生成的LoFi模型在能源规模上与Annex 60基准具有高度一致性,所提出的校准工作流程稳健地提高了回水温度瞬变和区域温度动态。此外,LoFi模型实现了数量级更快的模拟,适用于年度能耗分析,而HiFi模型在所需热量与实际交付热量不同时是必要的,尤其是在瞬态和峰值评估中。
英文摘要:
Accurate building energy models are crucial for analyzing sector-coupled energy systems, where buildings interact with electrified heating, energy storage, and advanced control across various scenarios. High-fidelity (HiFi) white-box models that resolve hydronic distribution and emitter dynamics can capture short-term transients, yet their numerical stiffness and computational burden limit long-term simulations and large-scale scenario exploration. Conversely, reduced-order low-fidelity (LoFi) representations enable rapid annual assessments but may fail to capture the hydronic- and control-induced dynamics that govern transient and peak behavior. This paper proposes a dual-fidelity, multi-zone white-box building modeling framework, which is called JanusBM, built on a novel topology-driven modeling tool RoomFlex6D, coupling a HiFi hydronic model and a LoFi ideal-load surrogate that removes explicit hydronic states in Modelica. To ensure applicability and physical consistency across time scales, we introduce a two-stage hybrid validation and calibration pipeline that uses complementary data: the IEA EBC Annex 60 benchmark for energy-scale validation and time-series measurements from real-world experimental buildings for hydronic dynamics-scale calibration. Results show that the generated LoFi models achieve a high degree of consistency with Annex 60 benchmark on the energy scale, and the proposed calibration workflow robustly improves loop-level return water temperature transients and zone-level temperature dynamics. Moreover, the LoFi model achieves orders-of-magnitude faster simulations suited to annual energy analyses, whereas the HiFi model becomes necessary when the required heat differs from the actual delivered heat due to distribution and control limitations, especially in transient and peak-oriented assessments.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。