arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2603.23012cs.CR
收藏

RTS-ABAC:面向变电站自动化系统的实时服务器辅助属性基授权与访问控制

RTS-ABAC: Real-Time Server-Aided Attribute-Based Authorization & Access Control for Substation Automation Systems

Karlsruhe Institute of Technology (KIT)(卡尔斯鲁厄理工学院)

Moritz Gstür, Gustav Keppler, Mohammed Ramadan, Ghada Elbez, Veit Hagenmeyer

AI总结:

本文提出RTS-ABAC,一种针对变电站自动化系统严格时延要求的实时服务器辅助属性基授权与访问控制方法,通过引入实时属性和时间依赖性策略评估与执行,提升通信安全性和抗攻击能力。

摘要:

关键能源基础设施日益依赖信息通信技术进行监控和控制,从而带来新的网络安全挑战。最近在该领域的进展,包括属性基访问控制(ABAC),尚未被现有的IEC 61850和IEC 62351标准充分解决。为了解决这个问题,我们提出了一种名为RTS-ABAC的新实时服务器辅助属性基授权和访问控制方法,专门针对变电站自动化系统(SAS)中固有的严格时延约束。我们通过引入实时属性和时间依赖性策略评估与执行,扩展了传统ABAC的概念。为了确保SAS通信的真实性和完整性,并保护SAS免受典型领域攻击,RTS-ABAC采用强制认证、授权和访问控制,通过线插入(BITW)方法对所有类型的SAS通信进行。为了评估RTS-ABAC,我们进行了基于测试床的性能分析和实验室应用演示。我们使用智能电子设备、合并单元和I/O箱通过GOOSE和SV协议进行通信,以演示其适用性。结果表明,RTS-ABAC能够安全地在SAS设备之间实现低延迟通信,多达99.82%的交换数据包的往返时间低于6毫秒。此外,评估结果表明,RTS-ABAC不仅适用于新建的SAS,还适用于现有变电站的改造升级。

英文摘要:

Critical energy infrastructures increasingly rely on information and communication technology for monitoring and control, which leads to new challenges with regard to cybersecurity. Recent advancements in this domain, including attribute-based access control (ABAC), have not been sufficiently addressed by established standards such as IEC 61850 and IEC 62351. To address this issue, we propose a novel real-time server-aided attribute-based authorization and access control for time-critical applications called RTS-ABAC. We tailor RTS-ABAC to the strict timing constraints inherent to the protocols employed in substation automation systems (SAS). We extend the concept of conventional ABAC by introducing real-time attributes and time-dependent policy evaluation and enforcement. To safeguard the authenticity, integrity, and non-repudiation of SAS communication and protect an SAS against domain-typical adversarial attacks, RTS-ABAC employs mandatory authentication, authorization, and access control for any type of SAS communication using a bump-in-the-wire (BITW) approach. To evaluate RTS-ABAC, we conduct a testbed-based performance analysis and a laboratory-based demonstration of applicability. We demonstrate the applicability using intelligent electronic devices, merging units, and I/O boxes communicating via the GOOSE and SV protocol. The results show that RTS-ABAC is able to secure low-latency communication between SAS devices, as up to 99.82 % of exchanged packets achieve a round-trip time below 6 ms. Moreover, the results of the evaluation indicate that RTS-ABAC is a viable solution to enhance the cybersecurity not only in a newly constructed SAS but also via retrofitting of existing substations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑