输入凸编码器-only 变换器用于快速且梯度稳定的建筑需求响应MPC

Input Convex Encoder-Only Transformer for Computationally Efficient Model Predictive Control in Building Demand Response

University College London(伦敦大学学院)

Kaipeng Xu, Zhuo Zhi, Keyue Jiang

AI总结:

本文提出输入凸编码器-only变换器(IC-EoT)以解决MPC中非凸优化问题,通过并行处理提升效率,减少求解时间,适用于建筑能源管理的实时控制。

摘要:

基于学习的模型预测控制(MPC)已成为建筑需求响应的强大策略,但其实际部署常受标准神经网络模型诱导的非凸优化问题阻碍。这些问题是由于非凸优化问题导致求解时间长和次优解,使长时间范围内的实时控制具有挑战性。虽然输入凸神经网络(ICNNs),如输入凸长短期记忆(IC-LSTMs),被开发以解决凸性问题,但它们的递归架构在预测时间增加时会面临高计算成本和梯度不稳定。为了克服这些限制,本文引入了输入凸编码器-only变换器(IC-EoT),这是一种新的架构,将变换器的并行处理能力与输入凸性的保证可处理性 结合起来。IC-EoT是在高保真协模拟框架中开发和评估的,使用Energym Python库与EnergyPlus建筑模拟器接口,并与其递归凸对应物(IC-LSTM)和标准非凸模型进行比较。结果表明,IC-EoT在结构上对影响递归ICNNs的梯度不稳定性具有免疫力,同时保持了可比的预测准确性。更关键的是,它显著减少了MPC求解时间;这种速度优势随着预测时间的增加而增长,在预测时间从一小时到八小时的范围内,IC-EoT比IC-LSTM快2.7到8.3倍。这种计算效率的飞跃使IC-EoT成为稳健且实用的解决方案,使在现实时间范围决策场景下建筑能源管理的有效实时MPC成为可能。

英文摘要:

Learning-based Model Predictive Control (MPC) has emerged as a powerful strategy for building demand response (DR). However, its practical deployment is often hindered by the non-convex optimization problems induced by standard neural network models. These problems lead to long solver times and a lack of global optimality guarantees, making long-horizon real-time control challenging. Because forecasting building thermal dynamics and energy consumption relies heavily on historical time-series data, Input Convex Neural Networks (ICNNs) tailored for temporal tasks have been developed to address this issue. Notable examples include Input Convex Recurrent Neural Networks (ICRNNs) and Input Convex Long Short-Term Memory (IC-LSTM). Although IC-LSTM improves the modelling capability of simpler ICRNNs, its recurrent architecture remains computationally expensive and, in the experiments reported here, exhibits numerical training instability at longer historical sequence lengths. To address these limitations, this paper introduces the Input Convex Encoder-Only Transformer (IC-EoT), which combines an encoder-only attention architecture with input convexity guarantees. IC-EoT was evaluated in a co-simulation framework using the Energym Python library and the EnergyPlus building simulator, and compared with IC-LSTM and standard non-convex models in residential and commercial testbeds. IC-EoT maintained predictive accuracy comparable to IC-LSTM, showed no non-finite loss events across 60 multi-seed training runs, and reduced mean per-epoch training time by 26.2% and 29.8% in the two testbeds. At the eight-hour prediction horizon, IC-EoT reduced mean MPC solution time by factors of 5.8 and 5.3 relative to IC-LSTM, while providing comparable closed-loop cost and comfort performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑