机器学习重建数字骨拉曼光谱实现非侵入式透皮检测系统性骨质疏松症
Machine learning reconstruction of digit bone Raman spectra enables noninvasive transcutaneous detection of systemic osteoporosis
AI总结:
利用机器学习重建透皮拉曼光谱,实现非侵入式检测系统性骨质疏松症,展示了在人体尸体研究中首次通过透皮组织提取诊断信息的可行性。
摘要:
骨质疏松症是一种全球性流行病,常在骨折发生后才被发现,主要由于缺乏使用双能X射线吸收法(DXA)等金标准方法的筛查机会。作为一种潜在的非电离辐射替代方法,我们提出了一种结合机器学习(ML)的透皮空间偏移拉曼光谱(SORS)方法,以恢复骨光谱并提取诊断信息。在一项覆盖正常、骨量减少和骨质疏松供体的人体尸体研究中,我们从多个空间偏移(0, 3, 和 6 mm)的透皮手指和相应暴露的指尖骨获取了配对的拉曼测量值。使用这个配对数据集,监督机器学习模型被训练以从透皮测量中重建暴露骨的拉曼光谱,从而直接从透皮组织中恢复骨生化特征。ML预测的骨光谱保留了生理上有意义的拉曼特征,并在四个关键的拉曼衍生指标上显示出正常组与骨质疏松组之间统计学显著差异(p < 0.05),代表了在人体尸体研究中首次通过透皮拉曼光谱区分临床已确立的骨健康类别。ML预测的光谱进一步与远端桡骨DXA T分数相关(r = 0.73,RMSECV = 1.4),接近使用暴露骨测量所达到的性能(r = 0.9,RMSECV = 0.8)。最后,两名志愿者的初步体内测量揭示了与尸体数据一致的骨相关透皮光谱特征,支持了转化可行性。这些结果为使用监督光谱提取进行非电离辐射的透皮骨健康评估奠定了基础。
英文摘要:
Osteoporosis, a major global epidemic, often goes undetected until a fracture occurs, largely due to poor access to screening using gold standard methods, such as dual-energy X-ray absorptiometry (DXA). As a potential nonionizing radiation alternative, we present a transcutaneous spatially offset Raman spectroscopy (SORS) approach combined with machine learning (ML) to recover bone spectra through overlying soft tissue and extract diagnostic information. In a human cadaveric study spanning normal, osteopenic, and osteoporotic donors, we acquired paired Raman measurements from transcutaneous fingers at multiple spatial offsets (0, 3, and 6 mm) and from the corresponding exposed finger bones. Using this paired dataset, supervised machine-learning models were trained to reconstruct exposed-bone Raman spectra from transcutaneous measurements, enabling direct recovery of bone biochemical signatures from transcutaneous tissue. The ML predicted bone spectra preserved physiologically meaningful Raman features and demonstrated statistically significant differences between normal and osteoporotic groups across four key Raman-derived metrics (p < 0.05), representing, to our knowledge, the first demonstration of transcutaneous Raman discrimination between clinically established bone-health categories in a human cadaveric study. The ML-predicted spectra further correlated with distal-radius DXA T-scores (r = 0.73, RMSECV = 1.4), approaching the performance achieved using exposed-bone measurements (r = 0.9, RMSECV = 0.8). Finally, preliminary in vivo measurements from two volunteers revealed clear bone-related transcutaneous spectral features consistent with cadaveric data, supporting translational feasibility. Together, these results establish a foundation for nonionizing radiation, transcutaneous Raman assessment of bone health using supervised spectral extraction from accessible measurement sites
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。