DINOv3结合测试时间校准用于CUBS v1上自动颈动脉内膜中层厚度测量
DINOv3 with Test-Time Calibration for Automated Carotid Intima-Media Thickness Measurement on CUBS v1
AI总结:
本文提出基于DINOv3的框架,用于颈动脉内膜中层复杂分割及后续CIMT测量,通过测试时间校准提升测量精度,实验结果显示其在CUBS v1数据集上具有较高的Dice和IoU指标,且误差范围在临床相关范围内。
摘要:
颈动脉内膜中层厚度(CIMT)通过B型超声测量是已建立的血管生物标志物,用于动脉粥样硬化和心血管风险分层。尽管已提出多种计算机化方法用于颈动脉边界分割和CIMT估计,但能联合解决分割和测量的鲁棒且可迁移的深度模型仍较少,特别是在视觉基础模型时代。受最近将DINOv3适应于医学分割和利用DINOv3在测试时间优化管道中的进展启发,我们研究了基于DINOv3的框架用于颈动脉内膜中层复杂分割及随后在Carotid Ultrasound Boundary Study(CUBS)v1数据集上的CIMT测量。我们的流程在固定图像分辨率下预测内膜中层带,按列提取上下边界,利用CUBS提供的每张图像校准因子校正图像缩放,并以物理单位报告CIMT。在三个患者层面的测试分割中,我们的方法在测试Dice上达到0.7739±0.0037,IoU为0.6384±0.0044。平均CIMT绝对误差为181.16±11.57μm,平均皮尔逊相关系数为0.480±0.259。在留出的验证子集(n=28)中,测试时间阈值校准将默认阈值下的平均绝对CIMT误差从141.0μm降至测量优化阈值下的101.1μm,同时减少系统偏差向零的倾向。相对于原始CUBS基准中经典计算机化方法报告的误差范围,这些结果将基于DINOv3的方法置于临床相关的约0.1 mm测量范围内。共同,我们的发现支持使用视觉基础模型进行可解释、校准感知的CIMT测量的可行性。
英文摘要:
Carotid intima-media thickness (CIMT) measured from B-mode ultrasound is an established vascular biomarker for atherosclerosis and cardiovascular risk stratification. Although a wide range of computerized methods have been proposed for carotid boundary delineation and CIMT estimation, robust and transferable deep models that jointly address segmentation and measurement remain underexplored, particularly in the era of vision foundation models. Motivated by recent advances in adapting DINOv3 to medical segmentation and exploiting DINOv3 in test-time optimization pipelines, we investigate a DINOv3-based framework for carotid intima-media complex segmentation and subsequent CIMT measurement on the Carotid Ultrasound Boundary Study (CUBS) v1 dataset. Our pipeline predicts the intima-media band at a fixed image resolution, extracts upper and lower boundaries column-wise, corrects for image resizing using the per-image calibration factor provided by CUBS, and reports CIMT in physical units. Across three patient-level test splits, our method achieved a mean test Dice of 0.7739 $\pm$ 0.0037 and IoU of 0.6384 $\pm$ 0.0044. The mean CIMT absolute error was 181.16 $\pm$ 11.57 $μ$m, with a mean Pearson correlation of 0.480 $\pm$ 0.259. In a held-out validation subset ($n=28$), test-time threshold calibration reduced the mean absolute CIMT error from 141.0 $μ$m at the default threshold to 101.1 $μ$m at the measurement-optimized threshold, while simultaneously reducing systematic bias toward zero. Relative to the error ranges reported in the original CUBS benchmark for classical computerized methods, these results place a DINOv3-based approach within the clinically relevant $\sim$0.1 mm measurement regime. Together, our findings support the feasibility of using vision foundation models for interpretable, calibration-aware CIMT measurement.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。