扩展gPET以实现多层PET仿真
Extending gPET for Multi-Layer PET Simulation
AI总结:
本文扩展gPET以支持多层PET探测器仿真,通过引入中间层结构实现灵活的几何建模,验证了不同配置的性能,并展示了其在DOI系统设计中的应用价值。
摘要:
深度交互(DOI)编码是一种有效策略,用于减少偏差点误差并保持空间分辨率,特别是在紧凑型小动物扫描仪中。为了实现高效驱动设计的DOI能力系统,我们扩展了GPU加速的蒙特卡罗工具包gPET,以支持灵活的多层探测器几何结构。gPET原有的三级分层探测器模型(面板-模块-晶体)通过引入一个中间“层”级别得到扩展,从而能够对堆叠的闪烁体架构进行参数化建模。光子传输算法相应地更新,以在多个层和探测器面板之间采样相互作用,同时保持GPU高效的内存使用。该框架通过三种扫描仪配置进行了验证:一种传统的单层环(H2RSPET-1CL),一种对齐的分层设计(H2RSPET-1CL-split),以及一种偏移双层设计(H2RSPET-2CL)。系统性能按照NEMA NU4-2008协议进行评估,使用灵敏度、空间分辨率和Derenzo幻影模拟,结合基于CASToR的最大似然期望最大化重建。H2RSPET-1CL和H2RSPET-1CL-split配置产生了统计上相同的击中分布,而H2RSPET-2CL表现出预期的偏移相互作用模式。H2RSPET-2CL的灵敏度与H2RSPET-1CL相比大致相当,通常在约2-5个百分点以内,而径向空间分辨率显著提高(0.8-1.6毫米 vs. 1.0-4.2毫米从中心到50毫米径向偏移)。运行时间性能在不同配置之间基本保持不变。因此,扩展的gPET框架能够快速灵活地模拟多层PET探测器,并支持高效优化DOI能力的PET系统设计。
英文摘要:
Depth-of-interaction (DOI) encoding is an effective strategy for reducing parallax error and preserving spatial resolution in positron emission tomography (PET), particularly in compact small-animal scanners. To enable efficient simulation-driven design of DOI-capable systems, we extend the GPU-accelerated Monte Carlo toolkit gPET to support flexible multi-layer detector geometries. The original three-level hierarchical detector model in gPET (panel-module-crystal) was expanded by introducing an intermediate "layer" level, enabling parameterized modeling of stacked scintillator architectures. The photon transport algorithm was correspondingly updated to sample interactions across multiple layers and detector panels while preserving GPU-efficient memory usage. The framework was validated using three scanner configurations: a conventional single-layer ring (H2RSPET-1CL), an aligned split-layer design (H2RSPET-1CL-split), and an offset dual-layer design (H2RSPET-2CL). System performance was evaluated following NEMA NU4-2008 protocols using sensitivity, spatial resolution, and Derenzo phantom simulations with CASToR-based maximum likelihood expectation maximization reconstruction. The H2RSPET-1CL and H2RSPET-1CL-split configurations produced statistically identical hit distributions, while H2RSPET-2CL exhibited the expected offset interaction patterns. Sensitivity of H2RSPET-2CL remained comparable to H2RSPET-1CL, generally within about 2-5 percent, while radial spatial resolution improved substantially (0.8-1.6 mm vs. 1.0-4.2 mm from the center to a 50 mm radial offset). Runtime performance remained essentially unchanged between configurations. The extended gPET framework therefore enables fast and flexible simulation of multi-layer PET detectors and supports efficient optimization of DOI-enabled PET system designs.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。