arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2603.06183cs.CLcs.AIcs.CV
收藏

CRIMSON:一种基于临床的LLM评估指标用于生成放射学报告评估

CRIMSON: A Clinically-Grounded LLM-Based Metric for Generative Radiology Report Evaluation

Department of Biomedical Informatics, Harvard Medical School(生物医学信息学系,哈佛医学院);Department of Radiation Oncology, Mass General Brigham(放射肿瘤科,麻省总医院与布里奇沃特医院);King Fahad Hospital, Al-Ahsa Health Cluster, Al Hofuf, Saudi Arabia(国王法赫德医院,阿尔阿萨卫生集群,阿尔霍夫,沙特阿拉伯);Ras-Tanura General Hospital, Ministry of Health, Eastern Province, Saudi Arabia(拉斯-坦纳医院,卫生部,东部省,沙特阿拉伯);Department of Medical Imaging, King Abdulaziz Medical City, Ministry of National Guard, Riyadh, Saudi Arabia(医学影像科,国王阿卜杜勒-阿齐兹医疗城,国民卫队部,利雅得,沙特阿拉伯)

Mohammed Baharoon, Thibault Heintz, Siavash Raissi, Mahmoud Alabbad, Mona Alhammad, Hassan AlOmaish, Sung Eun Kim, Oishi Banerjee, Pranav Rajpurkar

AI总结:

CRIMSON是一种基于临床的LLM评估指标,用于评估生成的放射学报告,通过考虑诊断正确性、上下文相关性和患者安全,提供更全面的评估方法。

摘要:

我们介绍了CRIMSON,一种用于胸部X光报告生成的临床导向评估框架,该框架基于诊断正确性、上下文相关性和患者安全来评估报告。与之前的指标不同,CRIMSON纳入了完整的临床背景,包括患者的年龄、指征和基于指南的决策规则,并防止正常或临床不显著的发现对总体评分产生不成比例的影响。该框架将错误分为涵盖假性发现、缺失发现和八个属性层面错误(例如位置、严重程度、测量和诊断过度解释)的综合性分类法。每个发现根据与住院心胸外科放射科医生合作开发的指南分配临床重要性级别(紧急、可操作的非紧急、不可操作的或预期/良性),从而实现基于严重性的加权,优先考虑临床后果显著的错误而非良性差异。CRIMSON通过与ReXVal中由六位认证放射科医生注释的临床重要错误计数的强一致性,以及通过我们引入的两个额外基准测试进行验证。在RadJudge中,一个针对临床具有挑战性的通过-失败场景的定向测试集中,CRIMSON与专家判断保持一致。在RadPref中,一个包含超过100对案例的更大放射科偏好基准测试中,每个案例有结构化的错误分类、严重性建模和三个心胸外科放射科医生的1-5级总体质量评分,CRIMSON实现了与放射科医生偏好的最强一致性。我们发布了该指标、评估基准测试、RadJudge和RadPref,以及一个微调的MedGemma模型,以实现报告生成的可重复评估,所有内容均在https://github.com/rajpurkarlab/CRIMSON上提供。

英文摘要:

We introduce CRIMSON, a clinically grounded evaluation framework for chest X-ray report generation that assesses reports based on diagnostic correctness, contextual relevance, and patient safety. Unlike prior metrics, CRIMSON incorporates full clinical context, including patient age, indication, and guideline-based decision rules, and prevents normal or clinically insignificant findings from exerting disproportionate influence on the overall score. The framework categorizes errors into a comprehensive taxonomy covering false findings, missing findings, and eight attribute-level errors (e.g., location, severity, measurement, and diagnostic overinterpretation). Each finding is assigned a clinical significance level (urgent, actionable non-urgent, non-actionable, or expected/benign), based on a guideline developed in collaboration with attending cardiothoracic radiologists, enabling severity-aware weighting that prioritizes clinically consequential mistakes over benign discrepancies. CRIMSON is validated through strong alignment with clinically significant error counts annotated by six board-certified radiologists in ReXVal (Kendalls tau = 0.61-0.71; Pearsons r = 0.71-0.84), and through two additional benchmarks that we introduce. In RadJudge, a targeted suite of clinically challenging pass-fail scenarios, CRIMSON shows consistent agreement with expert judgment. In RadPref, a larger radiologist preference benchmark of over 100 pairwise cases with structured error categorization, severity modeling, and 1-5 overall quality ratings from three cardiothoracic radiologists, CRIMSON achieves the strongest alignment with radiologist preferences. We release the metric, the evaluation benchmarks, RadJudge and RadPref, and a fine-tuned MedGemma model to enable reproducible evaluation of report generation, all available at https://github.com/rajpurkarlab/CRIMSON.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑