小瓶,大管:量化并解决数据中心对公共水系统的影响
Small Bottle, Big Pipe: Quantifying and Addressing the Impact of Data Centers on Public Water Systems
AI总结:
本文研究了美国数据中心冷却用水需求对公共水系统的影响,指出若2024年用水强度持续,到2030年可能需要697-1,451百万加仑的新水容量,提出通过报告峰值用水、社区合作、水容量中性等措施应对需求。
摘要:
水是数据中心的关键资源,也是高效的冷却手段。然而,满足数据中心日益增长的用水需求需要大量峰值用水,而许多美国社区无法提供,尤其是在最热的夏季。这种被忽视的水容量限制已成为数据中心的瓶颈,迫使运营商依赖效率较低的干冷,进一步在夏季高峰时加剧电力网络压力。本文聚焦美国数据中心用于冷却的直接用水量,并分析其对公共水系统的影响。我们的分析表明,若2024年的用水强度持续,则到2030年,美国数据中心可能需要697-1,451百万加仑的新水容量,与纽约市的日均供应量(约1,000百万加仑)相当。在乐观情景下,若年复合用水强度减少10%,水容量需求降至227-604百万加仑,尽管高IT负载仍可能需要足够的容量,以假设供应纽约市的一半。新水容量的总估值约为100亿美元,最高可达580亿美元。这些影响主要集中在托管数据中心的社区。最后,我们提出了应对美国数据中心日益增长的水容量需求的建议,包括报告峰值用水、发展企业-社区合作、采用水容量中性方法(俗称“管中性”)以允许社区保留有限的水容量资源,以及实施协调的水-电力规划,以负责任地利用水减少峰值电力需求,并有机会利用多余电力减轻对公共水系统的影响。
英文摘要:
Water is a critical resource for data centers and an efficient means of cooling. However, meeting the growing water demand of data centers requires substantial peak water withdrawals, which many communities in the United States cannot supply, especially during the hottest days of the year. This largely overlooked water capacity constraint is emerging as a bottleneck for data centers and can force operators to rely on less efficient dry cooling, further stressing the power grid during summer peaks. In this paper, we focus on the direct water withdrawal of U.S. data centers for cooling and examine their impacts on public water systems. Our analysis indicates that, if the 2024 water use intensity persists, U.S. data centers could collectively require 697-1,451 million gallons per day (MGD) of new water capacity through 2030, comparable to New York City's average daily supply of roughly 1,000 MGD. Under an optimistic scenario with a compound annual water use intensity reduction by 10%, the water capacity demand decreases to 227-604 MGD, although high-growth IT loads could still require enough capacity to hypothetically supply about half of New York City for most of the year. The total valuation of the new water capacity is on the order of \$10 billion, reaching up to \$58 billion in the high-growth case. These impacts are highly concentrated on communities hosting data centers. Finally, we provide recommendations to address the growing water capacity demand of U.S. data centers, including reporting peak water use, developing corporate-community partnerships, adopting a Water Capacity Neutral approach (colloquially "Pipe Neutral") to allow host communities to retain limited water capacity resources, and implementing coordinated water-power planning to responsibly leverage water for peak power reduction and opportunistically utilize surplus power to mitigate impacts on public water systems.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。