arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2603.02268cs.LGcs.AI
收藏

PRISM:探索异构预训练EEG基础模型迁移至临床鉴别诊断

PRISM: Exploring Heterogeneous Pretrained EEG Foundation Model Transfer to Clinical Differential Diagnosis

Indian Institute of Technology Mandi, India(印度理工学院曼迪分校);NeuroDx, India(NeuroDx)

Jeet Bandhu Lahiri, Parshva Runwal, Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Siddharth Panwar, Sandeep Singh

AI总结:

PRISM通过异构预训练EEG模型在临床鉴别诊断中表现优异,证明多样性优于规模,揭示评估因素对模型排名的影响。

摘要:

EEG基础模型通常在狭窄来源的临床档案上进行预训练,并在相同生态系统的基准上进行评估,这让人不清楚表示是否编码神经生理还是记录分布的伪影。我们介绍了PRISM(具有代表性不变信号模型),一种在两个轴上被剥离的遮蔽自动编码器——预训练人口和下游适应——其架构和预处理固定。我们比较了一个狭窄来源的欧盟/美国语料库(TUH + PhysioNet)与一个地理上多样化的池,该池通过多个EEG系统添加了多中心南亚临床记录。三个发现出现。首先,狭窄来源的预训练在分布匹配的基准上产生了更强的线性探测,而多样化的预训练在微调下产生了更具适应性的表示——这种权衡在单协议评估下是不可见的。在三个来源语料库上训练的PRISM在大多数任务上匹配或优于REVE(92个数据集,60000+小时),证明了有针对性的多样性可以替代无差别规模,并且数据集数量是模型比较中的混杂变量。第二,在一个具有挑战性且此前未测试的任务上——通过癫痫发作间期EEG区分癫痫与诊断模仿者——多样化的检查点比狭窄来源的检查点在平衡准确率上高出12.3个百分点,这是所有评估中最大的差距。第三,EEG-Bench和EEG-FM-Bench之间的系统不一致会反转相同数据集上的模型排名,最高可达24个百分点;我们确定了六个具体来源,包括分割构造、检查点选择、段长和标准化,显示这些因素以非加法的方式相互作用。

英文摘要:

EEG foundation models are typically pretrained on narrow-source clinical archives and evaluated on benchmarks from the same ecosystem, leaving unclear whether representations encode neural physiology or recording-distribution artifacts. We introduce PRISM (Population Representative Invariant Signal Model), a masked autoencoder ablated along two axes -- pretraining population and downstream adaptation -- with architecture and preprocessing fixed. We compare a narrow-source EU/US corpus (TUH + PhysioNet) against a geographically diverse pool augmented with multi-center South Asian clinical recordings across multiple EEG systems. Three findings emerge. First, narrow-source pretraining yields stronger linear probes on distribution-matched benchmarks, while diverse pretraining produces more adaptable representations under fine-tuning -- a trade-off invisible under single-protocol evaluation. Trained on three source corpora, PRISM matches or outperforms REVE (92 datasets, 60,000+ hours) on the majority of tasks, demonstrating that targeted diversity can substitute for indiscriminate scale and that dataset count is a confounding variable in model comparison. Second, on a clinically challenging and previously untested task -- distinguishing epilepsy from diagnostic mimickers via interictal EEG -- the diverse checkpoint outperforms the narrow-source checkpoint by +12.3 pp balanced accuracy, the largest gap across all evaluations. Third, systematic inconsistencies between EEG-Bench and EEG-FM-Bench reverse model rankings on identical datasets by up to 24 pp; we identify six concrete sources including split construction, checkpoint selection, segment length, and normalization, showing these factors compound non-additively.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑