arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.24247eess.SYcs.SY
收藏

基于数据驱动线性化的方法用于中压电力分配系统电弧故障预测

Data-Driven Linearization based Arc Fault Prediction in Medium Voltage Electrical Distribution System

ABB Ability Innovation Center(ABB能力创新中心);Indian Institute of Technology, Tirupati(蒂鲁帕蒂印度理工学院);BITS Pilani Hyderabad Campus(比拉尼理工学院海德拉巴校区);Indian Institute of Science Education and Research, Kolkata(加尔各答科学教育研究印度研究所)

Mihir Sinha, Kriti Thakur, Prasanta K. Panigrahi, Alivelu Manga Parimi, Mayukha Pal

AI总结:

本文提出基于数据驱动线性化的方法,用于中压电力分配系统中高阻抗电弧故障的早期预测,通过线性化处理提升故障检测的准确性和时效性。

摘要:

中压电力分配系统中的高阻抗电弧故障(HIAFs)由于其低故障电流水平和非线性瞬态行为而难以检测。传统检测算法在动态波形场景下的预测能力普遍不足。本研究提出了一种独特的数据驱动线性化(DDL)框架,用于早期预测HIAFs,兼具可解释性和可扩展性。所提出的方法通过坐标嵌入和多项式变换将非线性电流波形转换为线性空间,从而精确建模故障前兆。测试波形总持续时间为0.5秒,在其中电弧故障发生在0.2秒至0.3秒之间。所提出的基于DDL的方法仅在故障前的健康区域(0.10秒至0.18秒)上训练,能够捕捉某些不可见的故障前兆,以准确预测故障发生于0.189秒,比实际故障发生时间早约0.011秒(即11毫秒)。特别是,该框架在0.189秒预测电弧故障的开始,显著早于实际故障发生时间0.200秒,展示了显著的早期预警能力。性能评估包括特征值分析、预测误差测量、误差增长率和波形再生保真度。这种早期预测证明了模型能够正确预见故障,这在防止现实世界故障和事故方面尤其有帮助。它确认了所提出的方法能够可靠地预测中压电力分配系统中的电弧故障。

英文摘要:

High-impedance arc faults (HIAFs) in medium-voltage electrical distribution systems are difficult to detect due to their low fault current levels and nonlinear transient behavior. Traditional detection algorithms generally struggle with predictions under dynamic waveform scenarios. This research provides our approach of using a unique data-driven linearization (DDL) framework for early prediction of HIAFs, giving both interpretability and scalability. The proposed method translates nonlinear current waveforms into a linearized space using coordinate embeddings and polynomial transformation, enabling precise modelling of fault precursors.The total duration of the test waveform is 0.5 seconds, within which the arc fault occurs between 0.2 seconds to 0.3 seconds. Our proposed approach using DDL, trained solely on the pre-fault healthy region (0.10 seconds to 0.18 seconds) effectively captures certain invisible fault precursors, to accurately predict the onset of fault at 0.189 seconds, which is approximately 0.011 seconds (i.e., 11 milliseconds) earlier than the actual fault occurrence. In particular, the framework predicts the start of arc faults at 0.189 seconds, significantly earlier of the actual fault incidence at 0.200 seconds, demonstrating substantial early warning capability. Performance evaluation comprises eigenvalue analysis, prediction error measures, error growth rate and waveform regeneration fidelity. Such early prediction proves that the model is capable of correctly foreseeing faults which is especially helpful in preventing real-world faults and accidents. It confirms that our proposed approach reliably predicts arc faults in medium-voltage power distribution systems

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑