一种200 dB动态范围的抗辐射delta-sigma电流数字转换器用于束流损失监测
A 200 dB Dynamic Range Radiation-Hard Delta-Sigma Current Digitizer for Beam Loss Monitoring
AI总结:
本文提出了一种200 dB动态范围的抗辐射delta-sigma电流数字转换器,用于高能物理中的束流损失监测,具备高分辨率和快速响应能力。
摘要:
本文描述了一种采用标准130 nm CMOS工艺制造的抗辐射电流模式delta-sigma ADC,其总电离剂量达到100 Mrad。通过100秒的积分窗口,实现的运算信号范围超过200 dB。该转换器设计用于高能物理中的束流损失监测应用,必须处理从1 mA到1 pA的输入电流跨度九个数量级,同时提供10 us的快速响应时间用于机器保护。为满足这些矛盾要求,架构利用delta-sigma转换提供的分辨率和采集时间之间的固有权衡:一级架构以20 MHz采样率在关键的10 us窗口内提供11位有效分辨率,用于约1 mA的临界电流。积分时间超过10秒可实现所需的亚皮安分辨率,用于精确的束流对准和背景监测。该芯片集成了两个独立通道,从1.2 V电源消耗25 mW,并依靠抗辐射技术如三重冗余数字逻辑、定制ESD保护和手动封闭布局用于关键模拟晶体管。经过100 Mrad的辐射后测量显示无显著性能下降,未校准的积分非线性度在1 mA到5 uA范围内仍保持在[+4, -5] LSBs内。该转换器的灵活性和抗辐射能力使其不仅适用于HL-LHC束流损失监测升级,还适用于其他在恶劣环境中的高精度电流测量应用。
英文摘要:
This manuscript describes a radiation-hardened current-mode delta-sigma ADC fabricated in a standard 130 nm CMOS technology and qualified for total ionizing doses up to 100 Mrad. The operational signal range achieved with a 100 s integration window exceeds 200 dB. The converter is designed for beam loss monitoring applications in high-energy physics, where it must handle input currents spanning nine decades, from 1 mA down to 1 pA, while providing a fast 10 us response time for machine protection. To meet these conflicting requirements, the architecture exploits the inherent trade-off between resolution and acquisition time provided by delta-sigma conversion: a first-order architecture, sampling at 20 MHz, delivers 11-bit effective resolution within the critical 10 us window for critical currents around 1 mA. Integration times above 10 s enable the sub-picoampere resolution required for precise beam alignment and background monitoring. The chip integrates two independent channels, consumes 25 mW from a 1.2 V supply, and relies on radiation-hardening techniques such as triple-redundant digital logic, custom ESD protections, and manual enclosed layout for critical analog transistors. Post-irradiation measurements up to 100 Mrad show no significant performance degradation, and the uncalibrated integral nonlinearity remains within [+4, -5] LSBs over the 1 mA to 5 uA range. The converter's flexibility and radiation tolerance make it suitable not only for the HL-LHC beam loss monitoring upgrade but also for other precision current measurement applications in harsh environments.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。