鲁棒性胶质瘤分割与体积测量无需T2-FLAIR:针对dropout训练的外部验证
Robust Glioblastoma Segmentation and Volumetry Without T2-FLAIR: External Validation of Targeted Dropout Training
AI总结:
本文通过外部验证证明了在无T2-FLAIR情况下,利用目标dropout训练的3D nnU-Net模型可保持胶质瘤分割性能,并显著降低全肿瘤分割误差和体积偏差。
摘要:
目的:对外部验证目标T2液体抑制反转恢复(T2-FLAIR)dropout以实现稳健的自动化胶质瘤分割和无T2-FLAIR的全肿瘤体积测量,同时在完整MRI协议可用时保持性能。方法:在本回顾性多数据集研究中,3D nnU-Net模型在BraTS 2021(n=848)上开发,并在独立的宾夕法尼亚大学胶质瘤队列(n=403)上进行外部验证。模型在有或无目标T2-FLAIR dropout的情况下进行训练,在训练期间零化T2-FLAIR通道。测试使用预指定的T2-FLAIR存在和不存在场景;不存在场景通过在推理时零化T2-FLAIR通道来模拟。主要终点是患者层面的总体区域间Dice相似性系数(DSC)。次要终点是区域特定的DSC、95百分位Hausdorff距离和Bland-Altman全肿瘤体积偏倚。结果:在外部验证中,完整MRI协议下的性能得以保持:总体中位DSC为94.8%(四分位距[IQR] 90.0%-97.1%)有dropout和95.0%(IQR 90.3%-97.1%)无dropout。在T2-FLAIR不存在的场景中,目标dropout将总体中位DSC从81.0%(IQR 75.1%-86.4%)提高到93.4%(IQR 89.1%-96.2%)。全肿瘤DSC从60.4%提高到92.6%,全肿瘤95百分位Hausdorff距离从17.24 mm降低到2.45 mm,全肿瘤体积偏倚从-45.6 mL降低到0.83 mL。结论:在独立的外部测试队列中,目标T2-FLAIR dropout在完整MRI协议下保持了胶质瘤分割性能,并在T2-FLAIR缺失时显著降低了全肿瘤分割误差和体积偏倚。这些发现支持目标序列dropout作为自动化胶质瘤分析在回顾性和异质性临床工作流程中的实用稳健策略。
英文摘要:
Objectives: To externally validate targeted T2 fluid-attenuated inversion recovery (T2-FLAIR) dropout for robust automated glioblastoma segmentation and whole-tumor volumetry without T2-FLAIR, while preserving performance when the full MRI protocol is available. Methods: In this retrospective multi-dataset study, 3D nnU-Net models were developed on BraTS 2021 (n=848) and externally validated on an independent University of Pennsylvania glioblastoma cohort (n=403). Models were trained with or without targeted T2-FLAIR dropout, zeroing the T2-FLAIR channel during training. Testing used prespecified T2-FLAIR-present and T2-FLAIR-absent scenarios; the absent scenario was simulated by zeroing the T2-FLAIR channel at inference. The primary endpoint was per-patient overall region-wise Dice similarity coefficient (DSC). Secondary endpoints were region-specific DSC, 95th percentile Hausdorff distance, and Bland-Altman whole-tumor volume bias. Results: In external validation, performance was preserved with the full MRI protocol: overall median DSC was 94.8% (interquartile range [IQR] 90.0%-97.1%) with dropout and 95.0% (IQR 90.3%-97.1%) without dropout. In the T2-FLAIR-absent scenario, targeted dropout improved overall median DSC from 81.0% (IQR 75.1%-86.4%) to 93.4% (IQR 89.1%-96.2%). Whole-tumor DSC improved from 60.4% to 92.6%, whole-tumor 95th percentile Hausdorff distance from 17.24 mm to 2.45 mm, and whole-tumor volume bias from -45.6 mL to 0.83 mL. Conclusions: In an independent external test cohort, targeted T2-FLAIR dropout preserved glioblastoma segmentation performance with the full MRI protocol and substantially reduced whole-tumor segmentation error and volumetric bias when T2-FLAIR was absent. These findings support targeted sequence dropout as a practical robustness strategy for automated glioblastoma analysis in retrospective and heterogeneous clinical workflows.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。