arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.19772quant-ph
收藏

多光子Hong-Ou-Mandel干涉实现明亮热源的超分辨率成像

Multiphoton Hong-Ou-Mandel Interference Enables Superresolution of Bright Thermal Sources

University of Nottingham(诺丁汉大学);University of Portsmouth(朴茨茅斯大学);Politecnico di Bari(巴里理工大学);Istituto Nazionale di Fisica Nucleare (INFN)(意大利国家核物理研究所)

Aiman Khan, Danilo Triggiani, Vincenzo Tamma

AI总结:

多光子Hong-Ou-Mandel干涉实现明亮热源的超分辨率成像,通过多光子干涉与单光子Fock态,提升成像精度并超越衍射极限。

摘要:

我们提出了一种量子光学方案,通过在光束分离器中利用多光子干涉与参考单光子Fock态,对横向位移的任意强度热源进行成像。通过获得输出中横向动量解析的L光子概率的解析形式,我们通过Fisher信息分析表明,利用多光子事件干涉采样的分离估计器在广泛的分离范围和亮度下表现出显著增强的精度。偶数光子数巧合表现出在子雷利范围内恒定的精度,证明了我们方案的量子超分辨率超越了衍射极限。对于平均每个帧发射N_s~1个光子的源(如热源的红外发射),我们方案的精度界限与N_s线性相关,展示了估计器相对于弱源N_s<<1的增强精度,并符合最终的量子缩放。最后,傅里叶平面中的横向动量分辨率利用粗像素大小的顺序δy~100μm,对于示例图像斑点大小σ_x~0.1μm,产生有限的成像精度,与现有方案的衍射限制直接成像和超分辨倒置干涉成像相比,后者受到粗像素大小的严重退化且使用受限。结合Hong-Ou-Mandel干涉仪相对简单的传感操作与多光子巧合检测任意明亮热源和内可变的横向光子动量分辨率,我们的方案提供了一种稳健的替代方案,用于非侵入式单粒子跟踪和成像纳米尺度的化学和生物系统中的明亮源。

英文摘要:

We present a quantum optical scheme for imaging transversely displaced thermal sources of arbitrary intensities by employing multiphoton interference with a reference single-photon Fock state at a beamsplitter. Obtaining an analytical form for transverse momenta-resolved $L$-photon probabilities in either output, we show via Fisher information analysis that separation estimators built using interference sampling of multiphoton events exhibit significantly enhanced precision vis-à-vis existing imaging schemes over a wide range of separations and brightness. Even-photon-number coincidences exhibit constant precision in the sub-Rayleigh regime, demonstrating quantum superresolution of our scheme beyond the diffraction limit. For sources emitting on average $N_s\sim1$ photon per frame (such as in IR emission of thermal sources), precision bounds for our scheme scale linearly in $N_s$, exemplifying an enhanced precision of estimators in relation to weak sources $N_s\ll1$, and matching the ultimate quantum scaling. Finally, transverse momenta resolution in the Fourier plane produces finite imaging precisions for intermediate and large source separations using coarse pixel sizes of order $δy\sim100\,μ\mathrm{m}$ for exemplary image spot sizes $σ_x \sim 0.1\, μ\mathrm{m}$, in contrast with existing schemes of diffraction-limited direct imaging and superresolved inversion interferometric imaging that are severely degraded by coarse pixel sizes and have limited use. Combining the relatively straightforward sensing operation of Hong-Ou-Mandel interferometers with multiphoton coincidence detection of arbitrarily bright thermal sources and inner variable resolution of transverse photonic momenta, our scheme offers a robust alternative to non-invasive single-particle tracking and imaging of bright sources in nanoscopic chemical and biological systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑