从线圈到表面退化:ICP风洞中烧蚀的完全耦合模拟
From Coils to Surface Recession: Multiphysics Simulation of Ablation in ICP Wind Tunnels
AI总结:
本文提出了一种用于ICP风洞中材料烧蚀模拟的多物理场耦合框架,通过高保真求解器实现从头到尾的模拟,准确预测热化学响应和烧蚀行为。
摘要:
本文提出了一种完全耦合的多物理场计算框架,用于预测感应等离子体(ICP)风洞中热防护系统的热化学材料响应。该框架整合了高保真纳维-斯托克斯等离子体求解器、电磁场求解器和不连续伽辽金材料响应求解器,采用分区耦合策略。这使该框架能够对伊利诺伊大学厄巴纳-香槟分校(UIUC)的350 kW Plasmatron X设施进行从头到尾的模拟,包括等离子体生成、电磁加热、近壁热化学和时间准确的材料烧蚀。该模型捕捉了ICP中的关键物理现象,如涡旋模式回流、焦耳加热驱动的等离子体生成以及洛伦兹力诱导的流体约束,并准确预测了在低压下亚音速到超音速喷流行为的转变。通过冷壁热流计和石墨烧蚀实验的验证显示,预测的驻点热流值很好地落在实验不确定性范围内,而完全耦合的模拟准确再现了测量的驻点温度历史和退化率,误差分别低于12%和10%。早期加热阶段的剩余差异归因于功率耦合效率、平衡烧蚀建模和材料属性数据集的不确定性。总体而言,该框架在ICP风洞环境中展示了强大的预测能力,并为改进高超音速材料测试计划的设计、解释和规划提供了基础。
英文摘要:
This work presents a multi-solver, coupled computational framework for predicting the thermo-chemical material response of thermal protection systems in inductively coupled plasma (ICP) wind tunnels. The framework integrates a high-fidelity Navier-Stokes plasma solver, an electromagnetic field solver, and a discontinuous-Galerkin material response solver using a partitioned coupling strategy. This enables an ab initio, end-to-end simulation of the 350 kW Plasmatron X facility at the University of Illinois Urbana-Champaign (UIUC), including plasma generation, electromagnetic heating, near-wall thermochemistry, and time-accurate material ablation. The model captures key ICP physics such as vortex-mode recirculation, Joule-heating-driven plasma formation, and Lorentz-force-induced flow confinement, and accurately predicts the transition from subsonic to supersonic jet behavior at low pressures. Validation against cold-wall calorimetry shows that predicted stagnation-point cold-wall heat fluxes fall well within experimental uncertainty, while coupled ablation simulations accurately reproduce measured stagnation temperature histories and recession rates with errors below 12% and 10%, respectively. Remaining discrepancies are attributed to uncertainties in power-coupling efficiency, equilibrium ablation modeling, and material property datasets. Sensitivity analyses reveal that a 10% variation in system efficiency can induce changes of up to 11% in steady- state surface temperature and 17% in recession rate, whereas an equivalent variation in material thermal conductivity results in comparatively minor deviations of about 1.5% and 0.5%, respectively. Overall, the framework demonstrates strong predictive capability for ICP wind tunnel environments and provides a foundation for improved design, interpretation, and planning of hypersonic material testing campaigns.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。