arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.13176cs.CV
收藏

单目无标记动作捕捉可实现上肢可达空间的定量评估

Monocular Markerless Motion Capture Enables Quantitative Assessment of Upper Extremity Reachable Workspace

Shriners Children’s Lexington(夏皮尔儿童医院莱克星顿分院);University of Kentucky Department of Physical Therapy(肯塔基大学物理治疗系);Shirley Ryan AbilityLab(希拉里·瑞安康复实验室);Northwestern University(西北大学);School of Electrical and Computer Engineering(电气与计算机工程学院);Georgia Institute of Technology(佐治亚理工学院);The Wallace H. Coulter Department of Biomedical Engineering(沃克·H·库勒生物医学工程系);Georgia Institute of Technology and Emory University(佐治亚理工学院和埃默里大学);Pennsylvania State University at Harrisburg(宾夕法尼亚州立大学哈里斯堡分校);Nationwide Children’s Hospital(全国儿童医院)

Seth Donahue, J. D. Peiffer, R. Tyler Richardson, Yishan Zhong, Shaun Q. Y. Tan, Benoit Marteau, Stephanie R. Russo, May D. Wang, R. James Cotton, Ross Chafetz

AI总结:

单目无标记动作捕捉技术用于评估上肢可达空间,通过对比不同摄像机配置验证其临床可行性及实用性。

摘要:

为了验证使用单个(单目)摄像机和人工智能(AI)驱动的无标记动作捕捉(MMC)技术,对上肢可达空间(UERW)进行定量分析的临床可行方法。对这些技术在特定临床任务中的客观评估和验证对于其在临床运动分析中的应用至关重要。AI驱动的单目MMC减少了在临床环境中的采用障碍,并有可能减少对这种常见临床评估分析的开销。九名无损伤的成年人执行了标准化的UERW任务,该任务包括在虚拟球体中心的躯干上分布的靶点进行抓取,靶点通过VR头盔显示。同时使用标记式动作捕捉系统和八台FLIR摄像机捕捉动作。我们对其中两个摄像机视角进行了单目视频分析,以比较前视和偏移摄像机配置。前视摄像机方向与标记式参考具有很强的一致性,表现出最小的平均偏差为$0.61 \pm 0.12$%的可达空间每八分之一(均值±标准差)。相比之下,偏移摄像机视角低估了达到的百分比工作空间(-5.66 ± 0.45%的可达空间)。结论:这些发现支持了前视单目摄像机配置在UERW评估中的可行性,特别是在前部工作空间评估中,与标记式动作捕捉的一致性最高。整体表现展示了临床实践中单摄像机评估的潜力。本研究提供了对单目MMC系统在UERW任务评估中进行验证的首次证明。通过减少技术复杂性,这种方法使定量上肢运动能力评估的广泛应用成为可能。

英文摘要:

To validate a clinically accessible approach for quantifying the Upper Extremity Reachable Workspace (UERW) using a single (monocular) camera and Artificial Intelligence (AI)-driven Markerless Motion Capture (MMC) for biomechanical analysis. Objective assessment and validation of these techniques for specific clinically oriented tasks are crucial for their adoption in clinical motion analysis. AI-driven monocular MMC reduces the barriers to adoption in the clinic and has the potential to reduce the overhead for analysis of this common clinical assessment. Nine adult participants with no impairments performed the standardized UERW task, which entails reaching targets distributed across a virtual sphere centered on the torso, with targets displayed in a VR headset. Movements were simultaneously captured using a marker-based motion capture system and a set of eight FLIR cameras. We performed monocular video analysis on two of these video camera views to compare a frontal and offset camera configurations. The frontal camera orientation demonstrated strong agreement with the marker-based reference, exhibiting a minimal mean bias of $0.61 \pm 0.12$ \% reachspace reached per octanct (mean $\pm$ standard deviation). In contrast, the offset camera view underestimated the percent workspace reached ($-5.66 \pm 0.45$ \% reachspace reached). Conclusion: The findings support the feasibility of a frontal monocular camera configuration for UERW assessment, particularly for anterior workspace evaluation where agreement with marker-based motion capture was highest. The overall performance demonstrates clinical potential for practical, single-camera assessments. This study provides the first validation of monocular MMC system for the assessment of the UERW task. By reducing technical complexity, this approach enables broader implementation of quantitative upper extremity mobility assessment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑