arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.12814astro-ph.HE
收藏

X射线线诊断法用于Centaurus团核心多相气体的X射线成像仪/Resolve观测

X-ray line diagnostics of the multi-phase gas in the Centaurus cluster core with XRISM/Resolve

Saitama University(埼玉大学);Institute of Space and Astronautical Science, JAXA(宇宙科学研究所,日本宇宙航空研究开发机构);Tokyo University of Science(东京理科大学);Waterloo Centre for Astrophysics, University of Waterloo(滑铁卢天体物理中心,滑铁卢大学);SRON Space Research Organisation Netherlands(荷兰空间研究所);Kyoto Sangyo University(京都产业大学);IRAP, CNRS, Université de Toulouse, CNES, UT3-UPS(红外与射电天文研究所,法国国家科学研究中心,图卢兹大学)
Marie Kondo, Kotaro Fukushima, Kazunori Suda, Anwesh Majumder, Kosuke Sato, Kyoko Matsushita, François Mernier, Kazuhiro Nakazawa, Aurora Simionescu, Jean-Paul … 展开作者

Marie Kondo, Kotaro Fukushima, Kazunori Suda, Anwesh Majumder, Kosuke Sato, Kyoko Matsushita, François Mernier, Kazuhiro Nakazawa, Aurora Simionescu, Jean-Paul Breuer, Yasushi Fukazawa, Ryuichi Fujimoto, Isamu Hatsukade, Kokoro Hosogi, Michael Loewenstein, Tom'aš Plšek, Ming Sun, Misaki Urata, Norbert Werner, Noriko Y. Yamasaki, Yutaka Fujita

AI总结:

利用XRISM/Resolve观测Centaurus团核心多相气体,通过高能分辨率分析发射线比确定双温度结构,发现电离温度随原子质量增加而上升,Fe的电离与激发温度相近,且共振散射效应显著。

摘要:

我们报告了使用XRISM/Resolve观测到的Centaurus团核心内部介质(ICM)的多温度结构。得益于其高能分辨率,Resolve使我们能够测量从Si到Fe的高离子化发射线的精细结构,并通过发射线比诊断法直接确定激发温度和电离温度。Centaurus核心的观测光谱很好地由碰撞电离平衡状态下的双温度热等离子体表示,而不是等温状态。发射线比诊断也支持这种双温度结构。特别地,观测到的发射线比显示出随着原子质量增加,电离温度呈上升趋势,而Fe的电离和激发温度几乎相同温度。所得到的发射线比,由两个温度ICM,约1.6和约3 keV表示,也与假设的径向单温度ICM沿视线方向投影在团核心时的预期数值相当。由于Resolve在闸门关闭时的低能灵敏度有限,我们使用XMM-Newton/RGS光谱研究了冷组分的影响,但最终并未影响我们的结果。观测到的Fe XXV He alpha共振线与禁线之间的通量比显示出约20%的减少,表明存在共振散射。

英文摘要:

We report the multi-temperature structure of the intracluster medium (ICM) in the Centaurus cluster core observed with XRISM/Resolve. Thanks to its high energy resolution, Resolve enables us to measure fine structures of highly ionized emission lines from Si to Fe and to directly determine the excitation temperature and the ionization temperature from the emission line ratio diagnostics. The observed spectrum in the Centaurus core is well-represented by a double-temperature thermal plasma at collisional ionization equilibrium state rather than an isothermal one. The line ratio diagnostics also support this biphasic temperature structure. Particularly, the observed line ratios show a trend of increasing ionization temperature with atomic mass, while the ionization and excitation temperatures of Fe show nearly the same temperature. The resultant line ratios, which are well-represented by the two temperatures ICM, ~ 1.6 and ~ 3 keV, are also fairly consistent with the expected numbers when assuming the radial single-temperature ICM was projected in the cluster core along the line of sight. Due to the limited low-energy sensitivity of the Resolve with the gate valve closed, we investigated the effect of the cool component using the XMM-Newton/RGS spectrum, but it ultimately did not affect our results. The observed flux ratio between the Fe XXV He alpha resonance and forbidden lines shows an about 20% reduction, suggesting the presence of resonant scattering.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑