arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.09732physics.optics
收藏

甘油与焦糖色素的混合物:一种可逆性增加组织透明度用于体外定量相位成像的解决方案

The mixture of glycerin with tartrazine: a solution to reversibly increase tissue transparency for in vitro quantitative phase imaging

Warsaw University of Technology(华沙理工大学);Medical University of Warsaw(华沙医科大学);Nencki Institute of Experimental Biology of the Polish Academy of Sciences(波兰科学院神经生物学研究所);Maria Sklodowska-Curie National Research Institute of Oncology(玛丽亚·斯克沃多夫斯卡-居里国家癌症研究所);Centre of Postgraduate Medical Education(医学后教育中心)

Mikolaj Krysa, Anna Chwastowicz, Malgorzata Lenarcik, Pawel Matrybak, Piotr Zdankowski, Maciej Trusiak

AI总结:

本研究提出了一种低成本且安全的甘油与焦糖色素混合物,用于提高组织透明度,从而实现高通量无标记定量相位成像。

摘要:

厚组织切片强烈散射和吸收光线,这限制了通过定量相位成像(QPI)模态进行的基于传输的无标记检查。在这里,我们介绍了一种简单、常温的光学澄清介质——甘油和焦糖色素溶液(GTS;60%甘油,10%焦糖色素)——该溶液在保持组织形态的同时,提高了50-80微米小鼠肝脏和肾脏切片的透明度,从而实现了快速、无标记的定量相位成像。利用傅里叶全息显微镜(FPM)和无镜头数字全息显微镜结合像素超分辨率(LDHM-PSR),我们证明了在GTS浸泡后,与磷酸盐缓冲液(PBS)相比,微结构特征的高通量可视化有了显著改善。这种改善通过相位梯度值的一像素滞后自相关显著增加得到定量确认,表明散射驱动的相位伪影减少以及重建相位图中的结构连续性增强。我们进一步表明,GTS在常温下可稳定数月,提供即时但持久的澄清效果,且随时间推移效果增强,可通过短暂的PBS清洗去除,从而在同一样本上进行下游多模式分析。最后,我们将GTS与最先进的澄清剂Ce3D进行基准测试,突显GTS作为一种低成本、安全、操作简便的替代方案,具有在常规高通量QPI基病理工作流程中广泛应用的潜力。

英文摘要:

Thick tissue sections strongly scatter and absorb light, which limits transmission-based label-free examination via quantitative phase imaging (QPI) modalities. Here we introduce a simple, room-temperature optical clearing medium - glycerol and tartrazine solution (GTS; 60 percent glycerol, 10 percent tartrazine) - that increases the transparency of 50-80 micron murine liver and kidney slices while preserving tissue morphology and enabling rapid, label-free quantitative phase imaging. Using Fourier ptychographic microscopy (FPM) and lensless digital holographic microscopy with pixel super-resolution (LDHM-PSR), we demonstrate markedly improved high-throughput visualization of microstructural features after GTS immersion compared with phosphate-buffered saline (PBS). The improvement is confirmed quantitatively by a significant increase in the one-pixel-lag autocorrelation of phase-gradient values, indicating reduced scattering-driven phase artifacts and enhanced structural continuity in reconstructed phase maps. We further show that GTS is stable for months at room temperature, provides instant yet durable clearing that improves over time, and can be removed by brief PBS washing, enabling downstream multimodal analyses on the same specimen. Finally, we benchmark GTS against the state-of-the-art clearing agent Ce3D, highlighting GTS as a low-cost, safe, operationally straightforward alternative with strong potential for routine, high-throughput QPI-based histopathology workflows.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑