利用结构光诱导的视觉现象测试再测可靠性
Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena
AI总结:
本研究通过结构光诱导视网膜现象,验证了知觉任务的高可靠性,为黄斑疾病筛查提供了可靠方法。
摘要:
结构光(SL)诱导的偏振感知提供了一种有前景的方法,用于早期检测如年龄相关性黄斑变性的视网膜疾病。我们研究了使用基于SL的刺激诱导视网膜现象的知觉任务的测试再测可靠性,对象为视力健康的人群。28名参与者经过全面的眼部检查,确认其视力健康(logMAR BCVA ~0.00)。其中25名参与者(n=50眼),年龄21至75岁,完成了两个相同的任务,间隔1至14天。使用产生旋转视网膜现象的SL基刺激,包含22个方位刷,我们测量了参与者能够可靠识别旋转方向的视网膜等距阈值$R_T$,通过改变中央障碍物的大小。该阈值反映了每个参与者的视网膜现象的视觉角度。我们使用两向混合效应模型计算了可靠性系数(组内相关系数,ICC),并进行了Bland-Altman分析以评估测试再测可靠性。对于右眼(RE)的ICC为0.83 [95% CI: 0.62 - 0.93],对于左眼(LE)为0.93 [95% CI: 0.84 - 0.97],表明可靠性良好。Bland-Altman分析显示,第一次和第二次测试之间,RE和LE的均值差异分别为-0.32°(SD: 1.51)和-0.12°(SD: 1.03),一致性范围分别为-3.28°至2.64°和-2.14°至1.89°,证实了强的一致性和无显著偏倚。这些结果表明,基于SL的知觉任务是一种可靠的评估偏振感知的方法,可能提高对影响黄斑健康疾病筛查的效果。
英文摘要:
Structured light (SL)-induced polarization perception presents a promising method for the early detection of macular diseases such as age-related macular degeneration. We investigated the test-retest reliability of a psychophysical task using SL-based stimuli to induce entoptic patterns in individuals with healthy vision. Twenty-eight participants underwent thorough eye examinations to confirm they had healthy eyes and good vision (logMAR BCVA ~0.00). Of these, 25 participants (n=50 eyes) aged 21 to 75 completed two identical tasks separated by 1 to 14 days. Using SL-based stimuli that produced a rotating entoptic pattern containing 22 azimuthal brushes, we measured the retinal eccentricity threshold $R_T$ at which participants could reliably identify the direction of rotation by varying the size of a central obstruction. This threshold reflects the visual angle of the pattern for each participant. We calculated the reliability coefficient (intraclass correlation coefficient, ICC) using a two-way mixed-effects model and conducted a Bland-Altman analysis to assess test-retest reliability. The ICC was 0.83 [95% CI: 0.62 - 0.93] for right eyes (RE) and 0.93 [95% CI: 0.84 - 0.97] for left eyes (LE), indicating good reliability. The Bland-Altman analysis showed a mean difference of -0.32° (SD: 1.51) and -0.12° (SD: 1.03) for RE and LE respectively between the first and second sessions, with limits of agreement ranging from -3.28° to 2.64° and -2.14° to 1.89° for RE and LE respectively, confirming strong agreement and no significant bias. These results demonstrate that SL-based psychophysical tasks are a reliable method for assessing polarization perception, potentially improving screening for diseases affecting macular health.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。