arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2602.08836physics.med-phphysics.optics
收藏

利用结构光诱导的视觉现象测试再测可靠性

Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena

Centre for Eye and Vision Research(眼与视觉研究中心);Entoptica Limited(Entoptica有限公司);Kazakh Eye Research Institute(哈萨克斯坦眼科研究所);Incoherent Vision Inc.(Incoherent Vision公司);University of Waterloo(滑铁卢大学);Idaho State University(爱达荷州立大学);University at Buffalo, State University of New York(纽约州立大学布法罗分校)

Taranjit Singh, Mukhit Kulmaganbetov, Zhangting Wang, Dmitry Pushin, Benjamin Thompson, Andrew Silva, Melanie Mungalsingh, Iman Salehi, Davis Garrad, David Cory, Dusan Sarenac

AI总结:

本研究通过结构光诱导视网膜现象,验证了知觉任务的高可靠性,为黄斑疾病筛查提供了可靠方法。

摘要:

结构光(SL)诱导的偏振感知提供了一种有前景的方法,用于早期检测如年龄相关性黄斑变性的视网膜疾病。我们研究了使用基于SL的刺激诱导视网膜现象的知觉任务的测试再测可靠性,对象为视力健康的人群。28名参与者经过全面的眼部检查,确认其视力健康(logMAR BCVA ~0.00)。其中25名参与者(n=50眼),年龄21至75岁,完成了两个相同的任务,间隔1至14天。使用产生旋转视网膜现象的SL基刺激,包含22个方位刷,我们测量了参与者能够可靠识别旋转方向的视网膜等距阈值$R_T$,通过改变中央障碍物的大小。该阈值反映了每个参与者的视网膜现象的视觉角度。我们使用两向混合效应模型计算了可靠性系数(组内相关系数,ICC),并进行了Bland-Altman分析以评估测试再测可靠性。对于右眼(RE)的ICC为0.83 [95% CI: 0.62 - 0.93],对于左眼(LE)为0.93 [95% CI: 0.84 - 0.97],表明可靠性良好。Bland-Altman分析显示,第一次和第二次测试之间,RE和LE的均值差异分别为-0.32°(SD: 1.51)和-0.12°(SD: 1.03),一致性范围分别为-3.28°至2.64°和-2.14°至1.89°,证实了强的一致性和无显著偏倚。这些结果表明,基于SL的知觉任务是一种可靠的评估偏振感知的方法,可能提高对影响黄斑健康疾病筛查的效果。

英文摘要:

Structured light (SL)-induced polarization perception presents a promising method for the early detection of macular diseases such as age-related macular degeneration. We investigated the test-retest reliability of a psychophysical task using SL-based stimuli to induce entoptic patterns in individuals with healthy vision. Twenty-eight participants underwent thorough eye examinations to confirm they had healthy eyes and good vision (logMAR BCVA ~0.00). Of these, 25 participants (n=50 eyes) aged 21 to 75 completed two identical tasks separated by 1 to 14 days. Using SL-based stimuli that produced a rotating entoptic pattern containing 22 azimuthal brushes, we measured the retinal eccentricity threshold $R_T$ at which participants could reliably identify the direction of rotation by varying the size of a central obstruction. This threshold reflects the visual angle of the pattern for each participant. We calculated the reliability coefficient (intraclass correlation coefficient, ICC) using a two-way mixed-effects model and conducted a Bland-Altman analysis to assess test-retest reliability. The ICC was 0.83 [95% CI: 0.62 - 0.93] for right eyes (RE) and 0.93 [95% CI: 0.84 - 0.97] for left eyes (LE), indicating good reliability. The Bland-Altman analysis showed a mean difference of -0.32° (SD: 1.51) and -0.12° (SD: 1.03) for RE and LE respectively between the first and second sessions, with limits of agreement ranging from -3.28° to 2.64° and -2.14° to 1.89° for RE and LE respectively, confirming strong agreement and no significant bias. These results demonstrate that SL-based psychophysical tasks are a reliable method for assessing polarization perception, potentially improving screening for diseases affecting macular health.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑