几何形状、类别不平衡与对齐对重建精度的影响——基于微CT仿真的评估

Influence of Geometry, Class Imbalance and Alignment on Reconstruction Accuracy -- A Micro-CT Phantom-Based Evaluation

IIT Dharwad(印度理工学院达瓦德分校)

Avinash Kumar K M, Samarth S. Raut

AI总结:

本研究通过微CT仿真实验,探讨了几何形状、类别不平衡和对齐对3D重建精度的影响,发现Otsu方法在多数几何中表现最佳,而Jaccard指数更适合评估薄壁结构精度。

摘要:

3D模型的创建精度取决于医学扫描的成像硬件、分割方法和网格处理技术等。几何类型、类别不平衡、体素和点云对齐对精度的影响仍需深入研究。本工作评估了重建流程中的误差,并探讨了不同分割算法和几何类型下体素和表面基于的精度指标的应用。使用SLA技术打印了一个球体、一个面罩和一个AAA,并使用微CT机器进行扫描。分割使用了GMM、Otsu和RG方法。通过KU算法对分割和参考模型进行对齐,并定量比较了Dice和Jaccard得分、精确度等指标。表面网格通过基于ICP的对齐过程与参考网格进行配准。评估了诸如法向距离和平均Hausdorff距离等指标。Otsu方法被发现是所有几何形状中最合适的方法。AAA由于其小壁厚和对齐问题导致低重叠得分。类别不平衡对AAA的特异性影响最为显著。基于表面的精度指标与基于体素的趋势不同。RG方法在球体上表现最佳,而GMM和Otsu在AAA上表现更好。面罩表面最易出错,可能由于ICP过程中的对齐问题。分割精度是重建过程中不同阶段误差的总和。在高类别不平衡和对齐敏感的情况下,高体素精度指标可能具有误导性。Jaccard指数比Dice更严格,更适合薄壁结构的精度评估。应确保体素和点云对齐,以对重建流程进行可靠的评估。

英文摘要:

The accuracy of the 3D models created from medical scans depends on imaging hardware, segmentation methods and mesh processing techniques etc. The effects of geometry type, class imbalance, voxel and point cloud alignment on accuracy remain to be thoroughly explored. This work evaluates the errors across the reconstruction pipeline and explores the use of voxel and surface-based accuracy metrics for different segmentation algorithms and geometry types. A sphere, a facemask, and an AAA were printed using the SLA technique and scanned using a micro-CT machine. Segmentation was performed using GMM, Otsu and RG based methods. Segmented and reference models aligned using the KU algorithm, were quantitatively compared to evaluate metrics like Dice and Jaccard scores, precision. Surface meshes were registered with reference meshes using an ICP-based alignment process. Metrics like chamfer distance, and average Hausdorff distance were evaluated. The Otsu method was found to be the most suitable method for all the geometries. AAA yielded low overlap scores due to its small wall thickness and misalignment. The effect of class imbalance on specificity was observed the most for AAA. Surface-based accuracy metrics differed from the voxel-based trends. The RG method performed best for sphere, while GMM and Otsu perform better for AAA. The facemask surface was most error-prone, possibly due to misalignment during the ICP process. Segmentation accuracy is a cumulative sum of errors across different stages of the reconstruction process. High voxel-based accuracy metrics may be misleading in cases of high class imbalance and sensitivity to alignment. The Jaccard index is found to be more stringent than the Dice and more suitable for accuracy assessment for thin-walled structures. Voxel and point cloud alignment should be ensured to make any reliable assessment of the reconstruction pipeline.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑