arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2602.05077physics.med-ph
收藏

横向振荡轨迹用于欠采样切片:LOTUS

Laterally Oscillating Trajectory for Undersampling Slices: LOTUS

Centre for Functional and Metabolic Mapping (CFMM), Robarts Research Institute, Western University(西方大学罗伯茨研究所功能与代谢映射中心);Department of Biomedical Engineering, Faculty of Engineering, Western University(西方大学工程学院生物医学工程系);Athinoula A Martinos Center for Biomedical Imaging, Massachusetts General Hospital(马萨诸塞州总医院阿蒂努拉·A·马丁诺斯生物医学成像中心);Department of Radiology, Harvard Medical School(哈佛医学院放射系);Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University(西方大学舒利希医学院和牙科学院医学物理系)

Mayuri Sothynathan, Paul I. Dubovan, Corey. A. Baron

AI总结:

LOTUS通过受控非相干混叠降低g因子,提升扩散MRI的重建精度和扫描效率。

摘要:

目的:虽然螺旋采样在扩散MRI中提供了信噪比优势,但其与同时多切片技术的结合仍相对未被探索。本研究介绍了一种名为横向振荡轨迹用于欠采样切片(LOTUS)的3D螺旋状k空间轨迹,旨在通过受控的非相干混叠来最小化g因子。为了帮助验证,我们还引入了一种稳健的方法来估计迭代非笛卡尔重建中的g因子。\n方法:使用LOTUS和他人提出的几种采集方案对数值假体进行模拟数据采样,定量比较所得图像质量与已知的地面真实值。从两名受试者中获取了带有两个层面加速因子(2x和4x)和两个切片加速因子(2x和4x)的扩散加权活体脑数据。计算估计的g因子图和各向异性分数图,以定量和定性比较轨迹性能。对于仿真和活体数据,均使用了带和不带压缩感知的重建。\n结果:仿真通常显示LOTUS相比其他轨迹在最高欠采样率下g因子降低(20%-31%),并且重建精度(均方误差、结构相似性指数和熵度量)有所提高。活体采集显示g因子优势和图像质量的改进与仿真结果相似。对于仿真和活体数据,LOTUS的改进随着同时切片数量的增加而增加。\n结论:通过允许更高的切片加速率,LOTUS显示出减少扫描时间的潜力,这对于扩散MRI尤其有益。

英文摘要:

Purpose: While spiral sampling offers SNR advantages for diffusion MRI, its acceleration with simultaneous multislice remains relatively unexplored. This study introduces Laterally Oscillating Trajectory for Undersampling Slices (LOTUS), which is a 3D spiral-like k-space trajectory that aims to minimize g-factor via controlled incoherent aliasing. To aid in validation, we also introduce a robust method to estimate g-factor for iterative non-Cartesian reconstructions. Methods: Simulated data sampling of a numerical phantom was performed using LOTUS and several acquisition schemes proposed by others to quantitatively compare the resulting image quality when compared to a known ground truth. Diffusion-weighted in vivo brain data from two subjects was acquired with two in-plane acceleration factors (2x and 4x), and two slice acceleration factors (2x and 4x). Estimated g-factor maps and fractional anisotropy maps were calculated to quantitatively and qualitatively compare trajectory performance. For both simulation and in vivo, reconstructions both with and without compressed sensing were utilized. Results: Simulations generally showed decreased g-factor (20%-31%, depending on trajectory, at highest undersampling rate) and improved reconstruction accuracy (mean-square error, structural similarity index, and entropy metrics) for LOTUS compared to the other trajectories. The in vivo acquisitions demonstrated g-factor benefits and qualitative image quality improvements that mirrored the simulation results. For both simulation and in vivo, improvements for LOTUS increased for higher numbers of simultaneous slices. Conclusion: By enabling higher rates of slice acceleration, LOTUS shows promise for decreasing scan time, which is especially beneficial for diffusion MRI.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑