保护能源物联网中的时间完整性:应对时钟漂移和Y2K38故障
Securing Time Integrity in Energy IoT Against Clock Drift and Y2K38 Failures
AI总结:
提出STGAT框架,结合漂移感知时间嵌入、时间自注意力和图注意力,检测能源物联网中的时钟漂移、同步偏移和Y2K38溢出等时间异常,准确率达95.7%。
摘要:
分布式物联网设备的时间完整性对于能源网络物理系统(如智能电网和微电网)的可靠运行至关重要。然而,物联网系统易受时钟漂移、时间同步操纵和时间戳不连续(如2038年(Y2K38)Unix溢出)的影响,这些都会破坏时间顺序。传统的异常检测模型假设时间戳可靠,无法捕捉时间不一致性。本文引入STGAT(时空图注意力网络),该框架在能源物联网系统中建模时间失真和设备间一致性。STGAT结合漂移感知时间嵌入和时间自注意力来捕捉单个设备上被破坏的时间演化,并使用图注意力来建模时间误差的空间传播。曲率正则化的潜在表示在几何上区分正常时钟演化与由漂移、同步偏移和溢出事件引起的异常。在具有受控时间扰动的能源物联网遥测数据上的实验结果表明,STGAT达到了95.7%的准确率,优于循环、Transformer和图基线,具有显著改进(d > 1.8, p < 0.001)。此外,STGAT将检测延迟降低了26%,实现了2.3时间步的延迟,同时在溢出、漂移和物理不一致下保持稳定性能。
英文摘要:
Time integrity across distributed Internet of Things (IoT) devices is fundamental to reliable sensing, control, and security in energy cyber-physical systems. However, operational energy IoT systems remain vulnerable to clock-drift escalation, time-synchronization manipulation, and catastrophic timestamp discontinuities, e.g., the Year 2038 (Y2K38) Unix epoch overflow. These failures violate timestamp monotonicity, distort temporal ordering, and introduce structured inconsistencies in system observations. Conventional anomaly detection models, which typically assume reliable and uniformly ordered timestamps, are therefore ill-equipped to capture timing-layer failures. This paper introduces STGAT (Spatio-Temporal Graph Attention Network), a clock-dynamics-aware anomaly detection solution that jointly models temporal distortion and inter-device consistency in energy IoT systems. STGAT integrates drift-aware temporal embeddings and temporal self-attention to capture non-uniform and corrupted time evolution within individual device streams, while graph attention models the spatial propagation of timing inconsistencies across interconnected nodes. A Jacobian-regularized latent representation further promotes geometric separation between nominal clock evolution and anomalous temporal deformation caused by drift escalation, synchronization offsets, jitter accumulation, and epoch-overflow events. Experimental evaluation on energy IoT telemetry augmented with controlled timing-layer perturbations shows that STGAT achieves 95.7% accuracy, 94.0% precision, 92.0% recall, 93.0% F1-score, and 0.97 AUC under the primary test setting. STGAT also reduces detection delay to 2.3 time steps, corresponding to a 26% improvement over the closest baseline, while maintaining stable performance under overflow-induced discontinuities, stealthy drift escalation, and temporally induced physical inconsistencies.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。