arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2601.07585cs.CV
收藏

鲁棒多中心结直肠肝转移的CT检测与分类:基础模型的应用

Robust Multicentre Detection and Classification of Colorectal Liver Metastases on CT: Application of Foundation Models

Maastricht University(马斯特里赫特大学);Siemens Healthcare GmbH(西门子医疗有限公司);The First Affiliated Hospital of Sun Yat-sen University(中山大学附属第一医院);Medical University of Gdańsk(格但斯克医科大学);Umeå University(于默奥大学);Lithuanian University of Health Sciences(立陶宛健康科学大学);University of Pisa(比萨大学);Maastricht University Medical Center+(马斯特里赫特大学医学中心+)
Shruti Atul Mali, Zohaib Salahuddin, Yumeng Zhang, Andre Aichert, Xian Zhong, Henry C. Woodruff, Maciej Bobowicz, Katrine Riklund, Juozas Kupčinskas, Lorenzo Fa… 展开作者

Shruti Atul Mali, Zohaib Salahuddin, Yumeng Zhang, Andre Aichert, Xian Zhong, Henry C. Woodruff, Maciej Bobowicz, Katrine Riklund, Juozas Kupčinskas, Lorenzo Faggioni, Roberto Francischello, Razvan L Miclea, Philippe Lambin

AI总结:

本研究提出基于基础模型的AI流程,用于多中心CT中结直肠肝转移的稳健检测与分类,通过整合不确定性量化和可解释性,提升了分类准确率和病变检测效率。

摘要:

结直肠肝转移(CRLM)是导致癌症相关死亡的主要原因之一,在多中心设置中可靠地进行CT检测仍具挑战性。我们开发了一种基于基础模型的AI流程,用于患者层面的CRLM分类和病变层面的检测,整合了不确定性量化和可解释性。使用了欧CanImage联盟的CT数据(n=2437)和一个外部TCIA队列(n=197)。在几种预训练模型中,UMedPT表现最佳,并通过MLP头进行微调用于分类,通过FCOS头进行病变检测。分类模型在综合测试集上实现了AUC为0.90和灵敏度0.82,在外部队列上灵敏度为0.85。排除最不确定的20%病例后,AUC提高到0.91,平衡准确率提高到0.86。决策曲线分析显示,阈值概率在0.30至0.40之间具有临床效益。检测模型总体识别了69.1%的病变,从30%增加到98%在病变大小四分位数中。Grad-CAM在高置信度病例中突显了与病变对应的区域。这些结果表明,基于基础模型的流程可以在异质CT数据上支持稳健且可解释的CRLM检测和分类。

英文摘要:

Colorectal liver metastases (CRLM) are a major cause of cancer-related mortality, and reliable detection on CT remains challenging in multi-centre settings. We developed a foundation model-based AI pipeline for patient-level classification and lesion-level detection of CRLM on contrast-enhanced CT, integrating uncertainty quantification and explainability. CT data from the EuCanImage consortium (n=2437) and an external TCIA cohort (n=197) were used. Among several pretrained models, UMedPT achieved the best performance and was fine-tuned with an MLP head for classification and an FCOS-based head for lesion detection. The classification model achieved an AUC of 0.90 and a sensitivity of 0.82 on the combined test set, with a sensitivity of 0.85 on the external cohort. Excluding the most uncertain 20 percent of cases improved AUC to 0.91 and balanced accuracy to 0.86. Decision curve analysis showed clinical benefit for threshold probabilities between 0.30 and 0.40. The detection model identified 69.1 percent of lesions overall, increasing from 30 percent to 98 percent across lesion size quartiles. Grad-CAM highlighted lesion-corresponding regions in high-confidence cases. These results demonstrate that foundation model-based pipelines can support robust and interpretable CRLM detection and classification across heterogeneous CT data.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑