CR-39 track detector signatures of slow neutron like signals in Heavy-water electrolysis

Indian Institute of Technology Kanpur(坎普尔印度理工学院)

Ankit Kumar, Tushar Verma, Pankaj Jain, Raj Ganesh Pala, K. P. Rajeev

AI总结:

利用硼涂层CR-39探测器在重水电解中检测到慢中子信号,通过对比未涂层对照探测器验证了慢中子通量,建立了低通量慢中子检测的实验协议。

摘要:

我们报告了在涉及D-Pd沉积在Pt阴极上的D₂O电解中,记录到与慢中子捕获事件一致的可重复轨迹探测器信号。通过使用硼涂层的CR-39(BCR)探测器,实现了对慢中子的灵敏度,这些探测器记录由¹⁰B(n,α)⁷Li反应产生的带电粒子轨迹。这些探测器被放置在与同样制备的未涂层CR-39对照探测器(CCR)相邻的位置,这些对照探测器对慢中子基本不敏感,用于量化当前实验条件下来自带电粒子和快中子的背景贡献。因此,可重复的差分探测器特征(BCR > CCR)表明慢中子通量。在多个独立的D₂O电解实验中,BCR表现出显著高于CCR的轨迹信号。在这些条件下,观测到的差分响应对应于约(6.7 ± 0.2)cm⁻²s⁻¹的推断探测器等效慢中子通量。去除磁场导致差分信号减少约6倍,表明对所施加磁场有很强的实证依赖性。相比之下,在其他条件相同的情况下进行的H₂O电解未产生可测量的差分探测器响应,证实了观察到的效果需要氘化电化学条件。这些结果仅作为与慢中子捕获一致的探测器特征报告,不提出任何理论解释。相反,这项工作建立了一种经过对照验证和探测器验证的实验协议,用于检测低通量慢中子,并提供了与涉及金属-氘化系统实验相关的实证约束。

英文摘要:

We report reproducible track-detector signals consistent with slow neutron capture events, recorded in D$_2$O electrolysis involving D-Pd deposited on Pt cathode. Sensitivity to slow neutrons was achieved using boron-coated CR-39 (BCR) detectors, which register charged particle tracks arising from the $^{10}$B$(n,α)^{7}$Li reaction. These detectors were positioned adjacent to identically prepared uncoated CR-39 control detectors (CCR), which are effectively insensitive to slow neutrons and serve to quantify background contributions from charged particles and fast neutrons under the present experimental conditions. A reproducible differential detector signature (BCR $>$ CCR) would thus indicative of slow neutron fluences. Across multiple independent D$_2$O electrolysis experiments in $0.25~\mathrm{T}$ field, the BCR exhibited significantly excess track signals relative to CCRs. Under these conditions, the observed differential response corresponds to an inferred detector-equivalent slow neutron flux of approximately $(6.7 \pm 0.2)~\mathrm{cm^{-2},s^{-1}}$. Removal of the magnetic field resulted in a reduction of the differential signal by a factor of $\sim6$, indicating a strong empirical dependence on the applied field. In contrast, H$_2$O electrolysis performed under otherwise identical conditions produced no measurable differential detector response, establishing the necessity of deuterated electrochemical conditions for the observed effect. The results are reported strictly as detector signatures consistent with slow neutron capture and do not assert any theoretical explanation. Instead, this work establishes a control verified and detector validated experimental protocol for detecting low flux slow neutrons, and provides empirical constraints relevant to slow neutron studies in experiments involving metal-deuteride systems.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑