arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2601.05979physics.optics
收藏

优化金属-介电元胞以增强在溶液中IgG浓度测定的灵敏度

Optimization of the metal-dielectric metasurface unit cell for sensitivity enhancement in determination of IgG concentration in solutions

O.Ya. Usikov Institute for Radiophysics and Electronics of the NAS of Ukraine(乌克兰国家科学院 O.Ya. 乌西科夫无线电物理与电子学研究所);B.Verkin Institute for Low Temperature Physics and Engineering of NAS of Ukraine(乌克兰国家科学院 B.维尔金低温物理与工程研究所);Leibniz Institute for Solid State and Materials Research(莱布尼茨固体与材料研究所)

K. S. Kuznetsova, V. A. Pashynska, Z. E. Eremenko

AI总结:

本研究通过优化金属-介电超材料单元胞,提升对水溶液中IgG浓度的检测灵敏度。

摘要:

本研究旨在开发一种优化单元胞几何结构的金属-介电传感器结构,用于确定水溶液中免疫球蛋白G(IgG)浓度。研究结合了实验和理论研究,利用微波介电度测量法和COMSOL软件进行数值建模。通过原微波介电度测量装置,在微波频率下获得了IgG水溶液的复介电常数(CP)值对蛋白质浓度的依赖关系。结果显示,IgG浓度的增加导致所研究溶液的CP值降低。通过实验获得的IgG水溶液的CP数据被用作微波金属-介电超材料单元胞的数值建模基础。由特氟龙基板和平面铜微谐振器组成的金属-介电超材料与临床实验室中使用的标准96孔板结合。优化获得的超材料单元胞表明,单元胞内铜微谐振器的尺寸和位置显著影响传感器对水溶液中IgG浓度的灵敏度。含有四个铜微谐振器的超材料单元胞为检测样品中IgG浓度的变化提供了最灵敏的平台。反射系数的频率偏移与蛋白质浓度的变化直接相关。为有效确定水溶液中IgG浓度开发了校准图。

英文摘要:

This study focuses on developing a metal-dielectric sensor structure with optimized unit cell geometry for determination of protein Immunoglobulin G (IgG) concentration in aqueous solutions. The research combines both experimental and theoretical investigations, utilizing the differential microwave dielectrometry method and numerical modeling with COMSOL software. Complex permittivity (CP) values dependence of IgG water solutions on the protein concentration was experimentally obtained at the microwaves using original microwave dielectrometer setup. It was shown that increase of IgG concentration resulted in the CP values of the solutions studied decrease. The experimentally obtained CP data for the IgG water solutions were used as a basis for microwave metal-dielectric metasurface unit cell numerical modeling. The metal-dielectric metasurface consisting of Teflon substrate and plane copper microresonators was combined with a standard 96-well microplate used in clinical laboratories. Optimization of the obtained metasurface unit cell revealed that the size and position of the copper microresonators within the unit cell significantly impact the sensor sensitivity for determining the IgG concentration in aqueous solutions. The metasurface with the unit cell containing four copper microresonators provided the most sensitive platform for detecting variations in the IgG concentration in the sample. The frequency shift of the reflection coefficient was directly related to changes in the protein concentration. The calibration graph was developed for effective determination of IgG concentrations in the aqueous solutions.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑