基于AlN压电微机械超声发射器的液体密度传感器,对液体粘度不敏感
A Liquid Density Sensor Based On AlN Piezoelectric Micromachined Ultrasonic Transmitter Insensitive to Liquid Viscosity
AI总结:
本研究提出一种基于AlN的PMUT液体密度传感器,通过理论计算和实验验证,实现对液体粘度不敏感的高精度密度测量。
摘要:
为克服传统液体密度传感器的局限性,已开发出基于MEMS的方法。然而,粘度-密度耦合效应常在高粘度液体中影响精度。尽管已提出各种解耦策略,但它们通常面临复杂性和低效率的问题。本研究提出了一种基于AlN的PMUT液体密度传感器,对粘度干扰不敏感。该传感器采用两个相同的PMUT,分别作为发射器和接收器。由发射器产生的超声波被液体表面反射并被接收器检测。理论计算表明,当激励频率保持不变时,接收到的电信号幅度与液体密度之间呈现特定关系,而粘度引起的信号幅度变化变得可以忽略不计。因此,通过校准PMUT液体密度传感器,通过拟合接收信号幅度与密度在0-100%甘油溶液中的关系,该设备可以在不考虑液体类型和粘度的情况下测量此范围内的密度。实验结果表明,该传感器可以使用甘油校准的拟合公式准确测量丙二醇溶液的密度,计算出的密度误差率在使用甘油校准的拟合公式测量丙二醇溶液与实际密度之间保持在0.125%以下,证明了对两种液体之间粘度差异的测量不敏感性。所提出的方法在高粘度环境中(80%-100%甘油溶液)的最大误差率低于2.5%,这比基于谐振频率的其他密度测量方法低20%。所开发的PMUT液体密度传感器的可测量密度范围从0.789到1.261 g/cm3。
英文摘要:
To overcome the limitations of conventional liquid density sensors, MEMS-based approaches have been developed. However, the viscosity-density coupling effect often compromises accuracy in high-viscosity liquids. Although various decoupling strategies have been proposed, they often suffer from complexity and inefficiency. This study presents an AlN-based PMUT liquid density sensor insensitive to viscosity interference. The sensor employs two identical PMUTs, functioning as transmitter and receiver, respectively. An ultrasonic wave generated by the transmitter is reflected by the liquid surface and detected by the receiver. Theoretical calculations demonstrate that when the excitation frequency remains constant, the amplitude of the received electrical signal exhibits a specific relationship with liquid density, while the viscosity-induced signal amplitude variation becomes negligible. Therefore, after calibrating the PMUT liquid density sensor by fitting the relationship between received signal amplitude and density across 0-100% glycerol solutions, the device can measure densities within this range regardless of liquid type and viscosity. Experimental results show that the sensor can accurately measure the density of the propylene glycol solutions using the glycerol-calibrated fitting formula, with the calculated density error rate between measured propylene glycol solutions using the glycerol-calibrated fitting formula and actual densities remains below 0.125%, demonstrating measurement insensitivity to viscosity differences between the two liquids. The proposed method achieves maximum error rates of less than 2.5% in high-viscosity environments (80%-100% glycerol solutions), which is 20% that of other density measurement methods based on resonant frequency. The developed PMUT liquid density sensor exhibits a measurable density range from 0.789 to 1.261 g/cm3.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。