基于配对比率和MFV统计的HPGe辐射传感器时间序列鲁棒寿命估计
Robust Lifetime Estimation from HPGe Radiation-Sensor Time Series Using Pairwise Ratios and MFV Statistics
AI总结:
本研究提出基于配对比率和MFV统计的鲁棒方法,用于高纯度锗探测器长时间序列数据的寿命估计,提升核物理实验中衰变参数提取的精度与稳定性。
摘要:
高纯度锗(HPGe)伽马射线探测器是核物理和天体物理学实验中的核心仪器,其中长期稳定性和可靠提取衰变参数至关重要。然而,标准的指数衰变分析通常受到拟合参数之间强相关性和对探测器相关波动和异常值的敏感性影响。在本研究中,我们提出了一种基于配对比率和斯蒂纳最频繁值(MFV)统计量的稳健分析框架,用于HPGe探测器衰变数据。通过形成背景减去净计数的点对比率,消除了对绝对探测器响应的依赖,消除了传统回归中固有的幅度-寿命相关性。所得到的配对寿命估计表现出重尾行为,这种行为可通过MFV有效总结,MFV是一种为这种分布设计的稳健估计量。在案例研究中,使用了一个长且稳定的HPGe探测器数据集。该数据是在一个低温核物理实验中收集的,旨在观测97Ru的216 keV伽马射线线。使用跨度约10个半衰期的测量数据,我们得到平均寿命为tau=4.0959±0.0007(统计)±0.0110(系统)天,对应半衰期为T1/2=2.8391±0.0005(统计)±0.0076(系统)天。这些结果表明,配对-MFV方法为核物理和核天体物理实验中长期持续的HPGe探测器数据分析提供了一种稳健且可重复的工具,特别是用于高精度衰变测量、探测器稳定性研究和低背景监控。
英文摘要:
High-purity germanium (HPGe) gamma-ray detectors are core instruments in nuclear physics and astrophysics experiments, where long-term stability and reliable extraction of decay parameters are essential. However, the standard exponential decay analyses of the detector time-series data are often affected by the strong correlations between the fitted parameters and the sensitivity to detector-related fluctuations and outliers. In this study, we present a robust analysis framework for HPGe detector decay data based on pairwise ratios and the Steiner's most frequent value (MFV) statistic. By forming point-to-point ratios of background-subtracted net counts, the dependence on the absolute detector response is eliminated, removing the amplitude-lifetime correlation inherent to conventional regression. The resulting pairwise lifetime estimates exhibit heavy-tailed behavior, which is efficiently summarized using the MFV, a robust estimator designed for such distributions. For the case study, a long and stable dataset from an HPGe detector was used. This data was gathered during a low-temperature nuclear physics experiment focused on observing the 216 keV gamma-ray line in 97-Ru. Using measurements spanning approximately 10 half-lives, we obtain a mean lifetime of tau = 4.0959 +/- 0.0007 (stat) +/- 0.0110 (syst) d, corresponding to a half-life of T1/2 = 2.8391 +/- 0.0005 (stat) +/- 0.0076 (syst) d. These results demonstrate that the pairwise-MFV approach provides a robust and reproducible tool for analyzing long-duration HPGe detector data in nuclear physics and nuclear astrophysics experiments, particularly for precision decay measurements, detector-stability studies, and low-background monitoring.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。