arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2512.19663cs.CVcs.AI

超越CLIP:基于知识的多模态Transformer用于糖尿病视网膜病变诊断中的跨模态对齐

Beyond CLIP: Knowledge-Enhanced Multimodal Transformers for Cross-Modal Alignment in Diabetic Retinopathy Diagnosis

Department of Medicine Stanford University Stanford, USA(医学系 斯坦福大学)

Argha Kamal Samanta, Harshika Goyal, Vasudha Joshi, Tushar Mungle, Pabitra Mitra

AI总结:

本文提出一种基于知识的多模态Transformer框架,通过整合视网膜图像、临床文本和结构化数据,提升糖尿病视网膜病变诊断中的跨模态对齐与检索性能。

摘要:

糖尿病视网膜病变(DR)是全球导致可预防失明的主要原因之一,亟需准确的自动化诊断系统。尽管通用领域视觉-语言模型如对比语言-图像预训练(CLIP)在自然图像任务中表现良好,但它们在医疗领域应用中表现不佳,尤其是在眼科图像的跨模态检索中。我们提出了一种新的知识增强的联合嵌入框架,通过多模态Transformer架构整合视网膜底片图像、临床文本和结构化患者数据,以解决医学图像-文本对齐的关键缺口。我们的方法采用分别的编码器处理每种模态:视觉Transformer(ViT-B/16)用于视网膜图像,Bio-ClinicalBERT用于临床叙述,以及多层感知机用于结构化的人口统计数据和临床特征。这些模态通过具有模态特定嵌入的联合Transformer进行融合,训练时使用包括模态对之间的对比损失、图像和文本的重建损失以及根据ICDR和SDRG方案的DR严重程度分级分类损失等多重目标。在巴西多标签眼科数据集(BRSET)上的实验结果表明,与基线模型相比,我们的方法取得了显著改进。我们的框架在文本到图像检索性能上接近完美,Recall@1为99.94%,相比微调后的CLIP的1.29%。同时,保持了最先进的分类准确性,SDRG方案的准确率为97.05%,ICDR方案的准确率为97.97%。此外,在未见的DeepEyeNet数据集上的零样本评估验证了强大的泛化能力,Recall@1为93.95%,远超微调后的CLIP的0.22%。这些结果表明,我们的多模态训练方法有效捕捉了医学领域的跨模态关系,建立了优越的检索能力和稳健的诊断性能。

英文摘要:

Diabetic retinopathy (DR) is a leading cause of preventable blindness worldwide, demanding accurate automated diagnostic systems. While general-domain vision-language models like Contrastive Language-Image Pre-Training (CLIP) perform well on natural image tasks, they struggle in medical domain applications, particularly in cross-modal retrieval for ophthalmological images. We propose a novel knowledge-enhanced joint embedding framework that integrates retinal fundus images, clinical text, and structured patient data through a multimodal transformer architecture to address the critical gap in medical image-text alignment. Our approach employs separate encoders for each modality: a Vision Transformer (ViT-B/16) for retinal images, Bio-ClinicalBERT for clinical narratives, and a multilayer perceptron for structured demographic and clinical features. These modalities are fused through a joint transformer with modality-specific embeddings, trained using multiple objectives including contrastive losses between modality pairs, reconstruction losses for images and text, and classification losses for DR severity grading according to ICDR and SDRG schemes. Experimental results on the Brazilian Multilabel Ophthalmological Dataset (BRSET) demonstrate significant improvements over baseline models. Our framework achieves near-perfect text-to-image retrieval performance with Recall@1 of 99.94% compared to fine-tuned CLIP's 1.29%, while maintaining state-of-the-art classification accuracy of 97.05% for SDRG and 97.97% for ICDR. Furthermore, zero-shot evaluation on the unseen DeepEyeNet dataset validates strong generalizability with 93.95% Recall@1 versus 0.22% for fine-tuned CLIP. These results demonstrate that our multimodal training approach effectively captures cross-modal relationships in the medical domain, establishing both superior retrieval capabilities and robust diagnostic performance.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑