arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2512.09159physics.optics
收藏

自由可控的单光频梳用于高灵敏度腔衰减光谱法

Freely controllable single-optical-frequency comb for highly sensitive cavity ring-down spectroscopy

Nagoya University(名古屋大学);National Metrology Institute of Japan (NMIJ/AIST)(日本国家计量院(NMIJ/AIST))

Norihiko Nishizawa, Shotaro Kitajima, Ningwu Liu, Ryohei Terabayashi, Daiki Hashimoto, Hisashi Abe, Hideki Tomita

AI总结:

本研究提出一种自由可控的单光频梳用于高灵敏度腔衰减光谱法,通过集中光能于吸收光谱重叠模式,实现灵敏度提升至4.2 x 10^(-11) cm^(-1)。

摘要:

直接梳谱光谱法是一种获取高精度光谱信息的有用工具。然而,由于梳状模式数量非常大,光能分散在这些模式上,每个梳状模式的光能极小,限制了高灵敏度光谱的灵敏度。如果我们能将光能集中在仅与吸收光谱重叠的梳状模式上,就可以在测量灵敏度上实现显著提高。在本研究中,我们开发了一种基于谱峰现象的自由可控光学频率梳源。利用CH4气体细胞,将重叠CH4吸收光谱的梳状模式转换为非线性回环镜中的背景抑制谱峰。通过光纤拉曼放大器演示了生成梳状的相干保持功率放大。随后,使用新开发的高分辨率光谱滤波器只过滤单个梳状模式。单个梳状模式的最大光功率估计超过10毫瓦。利用生成的可控梳的单个选定模式测量高 finesse 光学腔的环形衰减信号。作为演示,通过梳状模式解析的腔环衰减光谱法(CRDS)准确测量了CH4吸收光谱的2v_3带,灵敏度高达4.2 x 10^(-11) cm^(-1)。该灵敏度比之前报道的基于梳状的CRDS高两个数量级。残差仅为0.29%,表明所提出的光谱仪在分子光谱分析中的高精度。这种方法可以扩展到其他波长范围,并且对高灵敏度、高分辨率的梳状解析光谱学是有用的。

英文摘要:

Direct comb spectroscopy is a useful tool for obtaining highly accurate spectroscopic information. However, as the number of comb modes is very large and the optical energy is dispersed over them, the optical energy per each comb mode is ultrasmall, limiting the sensitivity of highly sensitive spectroscopy. If we can concentrate the optical energy into the comb modes that only overlap with the absorption spectra, we can demonstrate drastic improvements in its measurement sensitivity. In this study, we developed a freely controllable optical frequency comb source based on the spectral peak phenomenon. The comb modes overlapping the CH4 absorption spectra were transformed into background-suppressed spectral peaks at the nonlinear loop mirror using a CH4 gas cell. Coherence-preserving power scaling of the generated comb was demonstrated using a fiber Raman amplifier. Subsequently, only the single-comb mode was filtered using a newly developed spectral filter with an ultrahigh resolution. The maximum optical power of a single comb was estimated to be more than 10 mW. The ring-down decay signal from the high-finesse optical cavity was measured using a single selected mode of the generated controllable comb. As a demonstration, the 2v_3 bands of the CH4 absorption spectra were accurately measured by comb-mode-resolved, cavity ring-down spectroscopy (CRDS) with high sensitivity up to 4.2 x 10^(-11) cm^(-1). This sensitivity is two orders of magnitude higher than that of previously reported comb-based CRDS. The residual was only 0.29 %, indicating the high accuracy of the proposed spectrometer for molecular spectral analysis. This approach can be extended to other wavelength ranges and is useful for highly sensitive, high-resolution, comb-resolved spectroscopy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑