单步激光打标和薄化生物相容性MEMS流量传感器
Single-step laser patterning and thinning of biocompatible MEMS flow sensor
AI总结:
本研究提出单步光纤激光微加工技术,用于制造生物相容性、自由站立的MEMS热流量传感器,实现高热响应和低生产成本。
摘要:
微电子机械系统(MEMS)热流量传感器越来越多地用于生物医学应用中的紧凑、低功耗流量监测。然而,基于硅的方法在传感器制造中受到高成本、刚性和多步骤洁净室工艺的限制。本研究提出了一种单步光纤激光微加工方法,用于从超薄钛箔中制造生物相容性、自由站立的MEMS热流量传感器。该过程结合了打标和局部薄化,单步工艺中完成,钛作为电阻传感元件。采用由阈值映射矩阵(TMM)和能量密度矩阵(EDM)组成的双矩阵优化方法,确定了优化参数,无需重复试错。对于局部薄化,通过顺序R-T扫描并加入冷却间隔,减少了高斯光束剖面的再沉积,实现了厚度从50 μm到20-30 μm的均匀减少。制造的传感器通过热系数电阻(TCR)测量、红外(IR)热成像和在人工通风系统控制下的稳态和循环条件下的空气流测试进行评估。制造的设备显示出稳定的TCR为3278 ppm/°C,速度与电阻之间的线性关系校准曲线具有R²=0.986,与固定在基板上的设计相比,自由站立结构设计在热响应方面提高了54%。该制造方法消除了光刻、湿/干蚀刻和晶圆键合的需要,使柔性、生物相容性流量传感器的快速、低成本生产成为可能。该方法可以应用于需要紧凑尺寸、灵活性、局部薄化和自由站立结构的其他MEMS设备。
英文摘要:
Micro-electro mechanical systems (MEMS) thermal flow sensors are increasingly used for compact, low-power flow monitoring in biomedical applications. However, silicon-based method for sensor fabrication is limited by high cost, rigidity, and multi-step cleanroom processes. This study presents a single-step fiber laser micromachining method for fabricating biocompatible, free-standing MEMS thermal flow sensors from ultrathin titanium foil. The process combines patterning and localized thinning in single-step process, with titanium serving as resistive sensing element. A dual-matrix optimization approach consisting of a Threshold Mapping Matrix (TMM) and Energy Density Matrix (EDM) was used to determine optimized parameters without repeated trial-and-error. For localized thinning, sequential R-T scans with cooling intervals reduced redeposition from the Gaussian beam profile and produced uniform thickness reduction from 50 μm to 20--30 μm. The fabricated sensors were evaluated through thermal coefficient resistance (TCR) measurement, Infrared (IR) thermography, and airflow tests under steady and cyclic conditions controlled by artificial ventilation system. The fabricated devices showed a stable TCR of 3278 ppm °C$^{-1}$, a linear relationship calibration curve between velocity and resistance with $R^2$=0.986 and a 54% improvement in thermal response was achieved with the free-standing structure design compared to substrate-fixed designs. This fabrication approach removes the need for photolithography, wet/dry etching, and wafer bonding, enabling faster and lower-cost production of flexible, biocompatible flow sensors. The method can be applied to other MEMS devices that require compact size, flexibility, localized thinning and free-standing structures.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。