AutoLugano:一种用于FDG-PET/CT上全自动淋巴瘤分割和卢加诺分期的深度学习框架
AutoLugano: A Deep Learning Framework for Fully Automated Lymphoma Segmentation and Lugano Staging on FDG-PET/CT
AI总结:
AutoLugano通过深度学习实现FDG-PET/CT上淋巴瘤的全自动分割与卢加诺分期,提升初始分期和治疗分层的准确性。
摘要:
目的:开发一个全自动深度学习系统AutoLugano,通过进行病变分割、解剖定位和自动卢加诺分期,实现端到端的淋巴瘤分类。方法:AutoLugano系统通过三个连续模块处理基线FDG-PET/CT扫描:(1)解剖引导的病变分割,一个3D nnU-Net模型,通过多通道输入进行训练,实现自动病变检测;(2)基于图谱的解剖定位,利用TotalSegmentator工具包,通过确定性的解剖规则将分割的病变映射到21个预定义的淋巴结区域;(3)自动卢加诺分期,将涉及区域的空间分布转化为卢加诺阶段和治疗组(局限期 vs. 进展期)。系统在公共autoPET数据集(n=1,007)上进行训练,并在外部验证于67名独立受试者上。性能通过准确率、灵敏度、特异度、F1分数进行区域涉及检测和分期一致性的评估。结果:在外部验证集上,所提出的模型表现出稳健的性能,达到了整体准确率88.31%、灵敏度74.47%、特异度94.21%和区域涉及检测的F1分数80.80%,优于基线模型。最值得注意的是,对于关键的临床任务治疗分层(局限期 vs. 进展期),系统达到了85.07%的高准确率,特异度90.48%和灵敏度82.61%。结论:AutoLugano代表了首个全自动、端到端的流程,能够将单个基线FDG-PET/CT扫描转化为完整的卢加诺分期。本研究展示了其在初始分期、治疗分层和支持临床决策中的强大潜力。
英文摘要:
Purpose: To develop a fully automated deep learning system, AutoLugano, for end-to-end lymphoma classification by performing lesion segmentation, anatomical localization, and automated Lugano staging from baseline FDG-PET/CT scans. Methods: The AutoLugano system processes baseline FDG-PET/CT scans through three sequential modules:(1) Anatomy-Informed Lesion Segmentation, a 3D nnU-Net model, trained on multi-channel inputs, performs automated lesion detection (2) Atlas-based Anatomical Localization, which leverages the TotalSegmentator toolkit to map segmented lesions to 21 predefined lymph node regions using deterministic anatomical rules; and (3) Automated Lugano Staging, where the spatial distribution of involved regions is translated into Lugano stages and therapeutic groups (Limited vs. Advanced Stage).The system was trained on the public autoPET dataset (n=1,007) and externally validated on an independent cohort of 67 patients. Performance was assessed using accuracy, sensitivity, specificity, F1-scorefor regional involvement detection and staging agreement. Results: On the external validation set, the proposed model demonstrated robust performance, achieving an overall accuracy of 88.31%, sensitivity of 74.47%, Specificity of 94.21% and an F1-score of 80.80% for regional involvement detection,outperforming baseline models. Most notably, for the critical clinical task of therapeutic stratification (Limited vs. Advanced Stage), the system achieved a high accuracy of 85.07%, with a specificity of 90.48% and a sensitivity of 82.61%.Conclusion: AutoLugano represents the first fully automated, end-to-end pipeline that translates a single baseline FDG-PET/CT scan into a complete Lugano stage. This study demonstrates its strong potential to assist in initial staging, treatment stratification, and supporting clinical decision-making.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。