arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2512.03339cs.CVcs.AIcs.LG
收藏

ProtoEFNet:用于在超声心动图中实现内在可解释的射血分数估计的动态原型学习

ProtoEFNet: Dynamic Prototype Learning for Inherently Interpretable Ejection Fraction Estimation in Echocardiography

Department of Applied Mathematics and Computer Science, Technical University of Denmark, Kongens Lyngby, Denmark(应用数学与计算机科学系,丹麦技术大学,Kongens Lyngby);Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada(电气与计算机工程系,不列颠哥伦比亚大学,温哥华,BC,加拿大);Vancouver General Hospital, Vancouver, BC, Canada(温哥华总医院,温哥华,BC,加拿大)

Yeganeh Ghamary, Victoria Wu, Hooman Vaseli, Christina Luong, Teresa Tsang, Siavash Bigdeli, Purang Abolmaesumi

AI总结:

ProtoEFNet通过动态原型学习和PAS损失提升超声心动图中射血分数估计的可解释性和准确性。

摘要:

射血分数(EF)是评估心脏功能和诊断如心力衰竭等疾病的关键指标。传统上,EF估计需要手动追踪和领域专业知识,使过程耗时且易受观察者间变异的影响。目前大多数用于EF预测的深度学习方法都是黑盒模型,透明度有限,这降低了临床信任。一些事后可解释性方法已被提出,以在预测后解释决策过程,但这些解释不指导模型的内部推理,因此在临床应用中可靠性有限。为了解决这个问题,我们引入了ProtoEFNet,一种新的基于视频的原型学习模型,用于连续EF回归。该模型学习动态时空原型,捕捉具有临床意义的心脏运动模式。此外,所提出的原型角度分离(PAS)损失在连续EF光谱上强制了判别性表示。我们在EchonetDynamic数据集上的实验表明,ProtoEFNet可以实现与非可解释模型相当的准确性,同时提供临床相关的见解。消融研究显示,所提出的损失通过将F1分数提高2%(从77.67±2.68提高到79.64±2.10)提升了性能。我们的源代码可在:https://github.com/DeepRCL/ProtoEF上获得。

英文摘要:

Ejection fraction (EF) is a crucial metric for assessing cardiac function and diagnosing conditions such as heart failure. Traditionally, EF estimation requires manual tracing and domain expertise, making the process time-consuming and subject to interobserver variability. Most current deep learning methods for EF prediction are black-box models with limited transparency, which reduces clinical trust. Some post-hoc explainability methods have been proposed to interpret the decision-making process after the prediction is made. However, these explanations do not guide the model's internal reasoning and therefore offer limited reliability in clinical applications. To address this, we introduce ProtoEFNet, a novel video-based prototype learning model for continuous EF regression. The model learns dynamic spatiotemporal prototypes that capture clinically meaningful cardiac motion patterns. Additionally, the proposed Prototype Angular Separation (PAS) loss enforces discriminative representations across the continuous EF spectrum. Our experiments on the EchonetDynamic dataset show that ProtoEFNet can achieve accuracy on par with its non-interpretable counterpart while providing clinically relevant insight. The ablation study shows that the proposed loss boosts performance with a 2% increase in F1 score from 77.67$\pm$2.68 to 79.64$\pm$2.10. Our source code is available at: https://github.com/DeepRCL/ProtoEF

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑