一种用于从床边监测器提取生理数据的分层计算机视觉管道

A Hierarchical Computer Vision Pipeline for Physiological Data Extraction from Bedside Monitors

Oxford University Clinical Research Unit(牛津大学临床研究单位);Trung Vuong Hospital(中ung Vuong医院);Nuffield Department of Medicine, University of Oxford(牛津大学医学系)
Vinh Chau, Khoa Le Dinh Van, Hon Huynh Ngoc, Binh Nguyen Thien, Hao Nguyen Thien, Vy Nguyen Quang, Phuc Vo Hong, Yen Lam Minh, Kieu Pham Tieu, Trinh Nguyen Thi … 展开作者

Vinh Chau, Khoa Le Dinh Van, Hon Huynh Ngoc, Binh Nguyen Thien, Hao Nguyen Thien, Vy Nguyen Quang, Phuc Vo Hong, Yen Lam Minh, Kieu Pham Tieu, Trinh Nguyen Thi Diem, Louise Thwaites, Hai Ho Bich

AI总结:

本文提出了一种基于计算机视觉的分层管道,用于从床边监测器屏幕自动提取生命体征数据,实现了高精度的监测器和ROI检测,提升了低资源环境下的数据整合能力。

摘要:

在许多资源有限的医疗环境中,床边监测器仍然是独立的遗留设备,缺乏网络连接,导致持续的互操作性差距,阻碍了生理数据无缝整合到电子健康记录(EHR)系统中。为了解决这一挑战而不需昂贵的硬件更换,我们提出了一种基于计算机视觉的管道,用于从床边监测器屏幕自动捕获和数字化生命体征数据。我们的方法采用一种分层检测框架,结合YOLOv11进行准确的监测器和感兴趣区域(ROI)定位,以及PaddleOCR进行稳健的文本提取。为了增强在可变相机角度和光照条件下的可靠性,一个几何校正模块在字符识别之前标准化屏幕视角。我们评估了该系统在一个包含6,498张图像的数据集上,这些图像来自开源语料库和越南现实世界重症监护室。模型在监测器检测上的平均平均精度(mAP@50-95)为99.5%,在生命体征ROI定位上的精度为91.5%。端到端提取精度超过98.9%的核心生理参数,包括心率、血氧饱和度SpO2和动脉血压。这些结果表明,一种轻量级、基于相机的方法可以可靠地将屏幕捕获中的无结构信息转换为结构化数字数据,提供了一种实用且可扩展的路径,以改善低资源环境中的信息可及性和临床记录。

英文摘要:

In many low-resource healthcare settings, bedside monitors remain standalone legacy devices without network connectivity, creating a persistent interoperability gap that prevents seamless integration of physiological data into electronic health record (EHR) systems. To address this challenge without requiring costly hardware replacement, we present a computer vision-based pipeline for the automated capture and digitisation of vital sign data directly from bedside monitor screens. Our method employs a hierarchical detection framework combining YOLOv11 for accurate monitor and region of interest (ROI) localisation with PaddleOCR for robust text extraction. To enhance reliability across variable camera angles and lighting conditions, a geometric rectification module standardizes the screen perspective before character recognition. We evaluated the system on a dataset of 6,498 images collected from open-source corpora and real-world intensive care units in Vietnam. The model achieved a mean Average Precision (mAP@50-95) of 99.5% for monitor detection and 91.5% for vital sign ROI localisation. The end-to-end extraction accuracy exceeded 98.9% for core physiological parameters, including heart rate, oxygen saturation SpO2, and arterial blood pressure. These results demonstrate that a lightweight, camera-based approach can reliably transform unstructured information from screen captures into structured digital data, providing a practical and scalable pathway to improve information accessibility and clinical documentation in low-resource settings.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑