arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2511.17360cond-mat.softphysics.flu-dyn
收藏

滴落至基底的流变学(DoS)的注意事项与建议

DoS Dos and Don'ts

Massachusetts Institute of Technology(麻省理工学院);University of Illinois Urbana-Champaign(伊利诺伊大学厄巴纳-香槟分校);University of Minnesota(明尼苏达大学)

Lucas Warwaruk, Konstantinos Zinelis, Randy H. Ewoldt, Christopher W. Macosko, Gareth H. McKinley

AI总结:

本研究通过定义DoS流变学的运算极限和模型界限,探讨了测量低粘度液体延伸松弛时间τ_E的可行性,并提出了新的性能指标'丝线捕捉率'以量化数据点数量。

摘要:

滴落至基底的流变学(DoS)流变学是一种用于测量低粘度液体延伸流变学的已知方法。然而,关于该技术能力和限制的明确指南却缺乏。在本工作中,我们定义了测量瞬时延伸粘度的运算极限,该极限直接基于丝线变细速率的观测,以及基于模型的计算液体粘度η和延伸松弛时间τ_E的界限。使用稀释的聚乙烯氧化物(PEO)和聚丙烯酰胺(PAM)溶液来探测可测量τ_E的下限,证明在满足(a)内在的德伯数(基于松弛时间与拉盖尔破裂时间尺度的比值)De≥O(0.1)以及(b)与空间和时间分辨率相关的仪器限制的情况下,可分辨的τ_E值低至0.1毫秒。该仪器限制通过我们定义的新指标量化,称为“丝线捕捉率”,这是一个“性能指标”(以赫兹为单位),可用于量化在弹性和毛细作用范围内可用于提取τ_E的数据点数量。我们还研究了对其他实验参数的敏感性,包括喷嘴半径和布恩数(Bo)的变化。在测试范围内(0.2 < Bo < 0.7)内,相同流体的延伸松弛时间变化小于±16%;然而,低粘度流体在Bo > 0.5时的实验表现出衰减的重力振荡,影响早期动态。总的来说,这些结果为可靠的DoS流变学提供了定量路线图,并证实了其用于测量弱弹性流体亚毫秒松弛时间的用途。

英文摘要:

Dripping-onto-Substrate (DoS) rheometry is a well-established method for measuring the extensional rheology of low-viscosity liquids. However, clear guidelines on the capabilities and limitations of the technique are lacking. In the present work, we define operational limits for measuring a transient extensional viscosity directly from observation of the rate of filament thinning, as well as model-based bounds on calculating a viscosity $η$ and extensional relaxation time $τ_E$ of a liquid using DoS. Dilute solutions of polyethylene oxide (PEO) and polyacrylamide (PAM) are used to probe the lower limit of measurable $τ_E$, demonstrating that values as low as 0.1 ms can be resolved, provided (a) the intrinsic Deborah number (based on the ratio of the relaxation time and the Rayleigh breakup time scale) is $De \geq \mathcal{O}(0.1)$ and (b) an instrumental constraint related to spatial and temporal resolution is satisfied. This instrumental constraint is quantified through a new metric we define as the \textit{filament capture rate}, a ``figure of merit'' (expressed in Hz) that can be used to quantify the number of data points within the elasto-capillary regime that are available for extraction of $τ_E$. We also investigate the sensitivity to other experimental parameters including variations in nozzle radius and Bond number ($Bo$). Across the tested range ($0.2 < Bo < 0.7$), extensional relaxation times for the same fluid vary by less than $\pm16$ \%; however, experiments with low viscosity fluids at $Bo > 0.5$ exhibit damped gravitational oscillations that affect early-time dynamics. Collectively, these results provide a quantitative roadmap for reliable DoS rheometry and affirm its use for measuring sub-millisecond relaxation times in weakly elastic fluids.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑