使用合成训练的Mask R-CNN实现CME自动检测
Automatic detection of CMEs using synthetically-trained Mask R-CNN
AI总结:
本研究提出使用合成训练的Mask R-CNN模型,实现对日冕物质抛射的自动检测,提高了CME分割的准确性和鲁棒性。
摘要:
日冕物质抛射(CMEs)是空间天气的主要驱动因素。为了评估CME的地球影响效应,以及其他科学目标,有必要可靠地识别和表征其形态和运动学特征。当前的CME识别方法要么受人为偏见影响,要么由于自动检测的不足而表现不佳。在本方法中,我们训练了深度卷积神经网络模型Mask R-CNN,以自动分割单张差分日冕仪图像中一个或多个CME的外层包络。经验训练数据集由10^5张合成日冕仪图像组成,这些图像具有已知的像素级CME分割掩膜。该数据集是通过结合平静日冕仪观测,利用GCS几何模型和光线追踪技术生成的合成白光CMEs。我们发现,基于模型训练的Mask R-CNN生成的分割掩膜是平滑且拓扑连接的。虽然推断的掩膜不反映复杂CME的详细外层包络,但神经模型可以更好地区分CME与其他径向运动的背景/前景特征,分割接近的多个同时发生的CME,并与不同仪器的图像一起工作。这在不依赖运动学信息的情况下完成,即仅使用单个输入差分图像。我们对1.6*10^4张合成验证图像获得了中位IoU=0.98,并在与COR2-A、COR2-B和LASCO C2日冕仪的115次观测的两个独立手动分割比较中,IoU=0.77。本文提出的方法可以与其他CME模型结合,生成更逼真的合成亮度图像,同时保留所需的形态学特征,并获得更稳健或定制的分割结果。
英文摘要:
Coronal mass ejections (CMEs) are a major driver of space weather. To assess CME geoeffectiveness, among other scientific goals, it is necessary to reliably identify and characterize their morphology and kinematics in coronagraph images. Current methods of CME identification are either subjected to human biases or perform a poor identification due to deficiencies in the automatic detection. In this approach, we have trained the deep convolutional neural model Mask R-CNN to automatically segment the outer envelope of one or multiple CMEs present in a single difference coronagraph image. The empirical training dataset is composed of 10^5 synthetic coronagraph images with known pixel-level CME segmentation masks. It is obtained by combining quiet coronagraph observations, with synthetic white-light CMEs produced using the GCS geometric model and ray-tracing technique. We found that our model-based trained Mask R-CNN infers segmentation masks that are smooth and topologically connected. While the inferred masks are not representative of the detailed outer envelope of complex CMEs, the neural model can better differentiate a CME from other radially moving background/foreground features, segment multiple simultaneous CMEs that are close to each other, and work with images from different instruments. This is accomplished without relying on kinematic information, i.e. only the included in the single input difference image. We obtain a median IoU=0.98 for 1.6*10^4 synthetic validation images, and IoU=0.77 when compared with two independent manual segmentations of 115 observations acquired by the COR2-A, COR2-B and LASCO C2 coronagraphs. The methodology presented in this work can be used with other CME models to produce more realistic synthetic brightness images while preserving desired morphological features, and obtain more robust and/or tailored segmentations.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。