arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2511.04079cs.CL
收藏

通过大规模训练和与云服务提供商方法的基准测试来改进放射学报告去标识化性能

Improving the Performance of Radiology Report De-identification with Large-Scale Training and Benchmarking Against Cloud Vendor Methods

Stanford University(斯坦福大学);JP Morgan Chase & Co(摩根大通公司);Sorbonne University(索邦大学);University of Oxford(牛津大学);NVIDIA(英伟达);HOPPR;University of Pennsylvania(宾夕法尼亚大学)

Eva Prakash, Maayane Attias, Pierre Chambon, Justin Xu, Steven Truong, Jean-Benoit Delbrouck, Tessa Cook, Curtis Langlotz

AI总结:

本文提出了一种基于变压器的去标识化模型,通过大规模训练和与商业系统的基准测试,实现了在放射学报告中更高效的PHI检测性能。

摘要:

目的:通过通过大量训练数据集扩展变压器模型来增强自动放射学报告去标识化性能,并通过与商业云服务供应商系统进行基准测试,以检测受保护的健康信息(PHI)。材料和方法:在本回顾性研究中,我们基于最先进的、基于变压器的、PHI去标识化流水线,通过在斯坦福大学的两个大型标注放射学语料库上进行微调,涵盖胸部X光、胸部CT、腹部/骨盆CT和脑部MRI报告,并将额外的PHI类别(AGE)引入架构中。模型性能在斯坦福和宾夕法尼亚大学(Penn)的测试集上进行评估,用于令牌级别的PHI检测。我们进一步评估了(1)使用“隐于 plain sight”方法的合成PHI生成的稳定性,以及(2)与商业系统的性能。在所有PHI类别上计算精确率、召回率和F1分数。结果:我们的模型在Penn数据集上实现了总体F1分数为0.973,在斯坦福数据集上达到0.996,优于或保持了先前的最先进模型性能。合成PHI评估显示在50个独立去标识化的Penn数据集中,检测性保持一致(总体F1:0.959 [0.958-0.960])。我们的模型在合成Penn报告上优于所有供应商系统(总体F1:0.960 vs. 0.632-0.754)。讨论:大规模、多模态训练提高了跨机构泛化能力和鲁棒性。合成PHI生成在保持数据效用的同时确保了隐私。结论:一个基于变压器的去标识化模型,通过在多样化的放射学数据集上进行训练,在PHI检测方面优于先前的学术和商业系统,并为安全的临床文本处理建立了新的基准。

英文摘要:

Objective: To enhance automated de-identification of radiology reports by scaling transformer-based models through extensive training datasets and benchmarking performance against commercial cloud vendor systems for protected health information (PHI) detection. Materials and Methods: In this retrospective study, we built upon a state-of-the-art, transformer-based, PHI de-identification pipeline by fine-tuning on two large annotated radiology corpora from Stanford University, encompassing chest X-ray, chest CT, abdomen/pelvis CT, and brain MR reports and introducing an additional PHI category (AGE) into the architecture. Model performance was evaluated on test sets from Stanford and the University of Pennsylvania (Penn) for token-level PHI detection. We further assessed (1) the stability of synthetic PHI generation using a "hide-in-plain-sight" method and (2) performance against commercial systems. Precision, recall, and F1 scores were computed across all PHI categories. Results: Our model achieved overall F1 scores of 0.973 on the Penn dataset and 0.996 on the Stanford dataset, outperforming or maintaining the previous state-of-the-art model performance. Synthetic PHI evaluation showed consistent detectability (overall F1: 0.959 [0.958-0.960]) across 50 independently de-identified Penn datasets. Our model outperformed all vendor systems on synthetic Penn reports (overall F1: 0.960 vs. 0.632-0.754). Discussion: Large-scale, multimodal training improved cross-institutional generalization and robustness. Synthetic PHI generation preserved data utility while ensuring privacy. Conclusion: A transformer-based de-identification model trained on diverse radiology datasets outperforms prior academic and commercial systems in PHI detection and establishes a new benchmark for secure clinical text processing.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑