本文通过二维地面响应分析校准,探讨了数值阻尼公式的应用,发现Rayleigh Mass阻尼在低速度对比站点中能更准确预测地面响应。
摘要:
准确建模地震波衰减对地面响应分析(GRAs)至关重要,旨在复制局部场地效应。然而,理论传递函数(TTFs)从GRAs往往在小应变阻尼比(D_min)设为实验室测量值时高估经验传递函数(ETFs)。先前研究通过在单维(1D)GRAs中放大D_min来考虑扩散和模式转换等无法在1D中捕捉的阻尼机制。尽管此方法提高了基本模式预测,但往往高估了更高模式。本研究探索了在四个地下阵列站点(Delaney Park(DPDA),I-15(I15DA),Treasure Island(TIDA),Garner Valley(GVDA))的二维(2D)GRAs中更直接建模明显阻尼。在每个站点,三种数值阻尼公式,Full Rayleigh,Maxwell,和Rayleigh Mass,使用传统D_min和通过场地特定校准获得的放大D_min(m×D_min)进行了实施。结果表明,适当的D_min乘数(m)与场地的速度对比相关。使用放大D_min,Full Rayleigh和Maxwell阻尼系统性高估了更高模式,而Maxwell阻尼也改变了模态峰。相比之下,Rayleigh Mass阻尼在三个站点中始终最接近ETFs,同时提供更快的计算性能。这些发现表明,放大D_min可以代表2D GRAs中未建模的衰减,特别是在低速度对比站点,并且频率依赖性公式如Rayleigh Mass阻尼比传统频率独立方法能更准确预测场地响应。
英文摘要:
Accurately modeling seismic wave attenuation is critical for ground response analyses (GRAs), which aim to replicate local site effects in ground motions. However, theoretical transfer functions (TTFs) from GRAs often overestimate empirical transfer functions (ETFs) when the small-strain damping ratio ($D_{\text{min}}$) is set equal to laboratory measurements. Prior studies addressed this by inflating $D_{\text{min}}$ in one-dimensional (1D) GRAs to account for apparent damping mechanisms such as diffraction and mode conversions that cannot be captured in 1D. Although this approach improved fundamental-mode predictions, it often overdamped higher modes. This study explores more direct modeling of apparent damping using two-dimensional (2D) GRAs at four downhole array sites: Delaney Park (DPDA), I-15 (I15DA), Treasure Island (TIDA), and Garner Valley (GVDA). At each site, three numerical damping formulations, Full Rayleigh, Maxwell, and Rayleigh Mass, were implemented using both conventional $D_{\text{min}}$ and an inflated $D_{\text{min}}$ ($m \times D_{\text{min}}$) obtained from site-specific calibration. Results show that the appropriate $D_{\text{min}}$ multiplier ($m$) correlates with the site's velocity contrast. Using inflated $D_{\text{min}}$, Full Rayleigh and Maxwell damping systematically overdamped higher modes, with Maxwell damping also shifting modal peaks. In contrast, Rayleigh Mass damping consistently achieved the closest match to ETFs at three of the four sites while offering faster computational performance. These findings demonstrate that inflated $D_{\text{min}}$ can represent unmodeled attenuation in 2D GRAs, particularly at sites with low velocity contrast, and that frequency-dependent formulations such as Rayleigh Mass damping can more accurately predict site response than traditional frequency-independent approaches.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。