Francesco Artibani, Leonardo Abbene, Antonino Buttacavoli, Manuele Bettelli, Gaetano Gerardi, Fabio Principato, Andrea Zappettini, Massimiliano Bazzi, Giacomo Borghi, Damir Bosnar, Mario Bragadireanu, Marco Carminati, Alberto Clozza, Francesco Clozza, Raffaele Del Grande, Luca De Paolis, Carlo Fiorini, Ivica Friscic, Carlo Guaraldo, Mihail Iliescu, Masahiko Iwasaki, Aleksander Khreptak, Simone Manti, Johann Marton, Pawel Moskal, Fabrizio Napolitano, Hiroaki Ohnishi, Kristian Piscicchia, Francesco Sgaramella, Michal Silarski, Diana Laura Sirghi, Florin Sirghi, Magdalena Skurzok, Antonio Spallone, Kairo Toho, Lorenzo G. Toscano, Oton Vazquez Doce, Johann Zmeskal, Catalina Curceanu, Alessandro Scordo

AI总结:

本文利用准半球形CZT探测器在DA$Φ$NE对撞机上实现基于时间的事件选择,首次观测到Kaonic铝原子的两个X射线跃迁,展示了CZT探测器在高辐射环境中的应用潜力。

摘要:

本文介绍了在DA$Φ$NE对撞机上使用单个准半球形镉锌碲(CZT)探测器进行基于时间的事件选择,以寻找来自Kaonic原子X射线跃迁的X射线信号的结果。为了降低测量X射线谱中的高背景水平,开发了一种专门的事件选择策略,利用e+e-碰撞与探测器信号之间的精确时间相关性。这种方法首次利用CZT探测器观测到Kaonic铝原子的两个特征X射线跃迁:对于5-4跃迁在50 keV处,观测到362±41(stat.)±20(sys.)个信号事件,背景事件为1698±197(stat.)±25(sys.),在5σ水平下,分辨率为9.2% FWHM;对于4-3跃迁在106 keV处,测量到295±50(stat.)±20(sys.)个信号事件,背景事件为2939±500(stat.)±16(sys.),在5σ水平下,分辨率为6.6 FWHM。通过这种基于时间的选择,实现了约95%的背景抑制。CZT探测器展示出的定时能力在80 ns窗口内有效地分离了时间相关的事件,为这些半导体在基于时间的X射线光谱学中的应用设定了重要的基准。这些结果突显了CZT基检测系统在高辐射环境中的未来精确测量中的潜力,为基本物理和更广泛领域中的紧凑、室温X射线和γ射线光谱仪铺平了道路。

英文摘要:

This work presents the results of a time-based event selection for searching X-ray signals from kaonic atom X-ray transition using a single quasi-hemispherical Cadmium-Zinc-Telluride (CZT) detector at the DA$Φ$NE collider. To mitigate the high background level in the measured X-ray spectrum, a dedicated event selection strategy was developed, exploiting the precise timing correlation between e+e- collisions and detector signals. This approach enabled, for the first time, the observation of two characteristic X-ray transitions from kaonic aluminum atoms using a CZT detector: for the 5-4 transition at 50~keV, 362~$\pm$~41~(stat.)~$\pm$~20~(sys.) signal events over 1698~$\pm$~197~(stat.)~$\pm$~25~(sys.) background events in 5$σ$ were observed, with a resolution of 9.2\%~FWHM; for the 4-3 transition at 106~keV, 295~$\pm$~50~(stat.)~$\pm$~20~(sys.) signal events over 2939~$\pm$~500~(stat.)~$\pm$~16~(sys.) background events in 5$σ$ were measured, with a resolution of 6.6 ~FWHM. A strong background suppression of approximately 95\% of the triggered data was achieved through this time-based selection. The demonstrated timing capability of the CZT detector proved highly effective in isolating time-correlated events within an 80 ns window, setting an important benchmark for the application of these semiconductors in timing-based X-ray spectroscopy. These results highlight the potential of CZT-based detection systems for future precision measurements in high-radiation environments, paving the way for compact, room-temperature X-ray and $γ$-ray spectrometers in fundamental physics and beyond.