arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2510.24849astro-ph.GAastro-ph.IM
收藏

使用多参考系与多方法基于HST测量天龙座II的自行

The Proper Motion of Draco II with HST using Multiple Reference Frames and Methodologies

The University of Virginia(弗吉尼亚大学);University of Toronto(多伦多大学);Space Telescope Science Institute(太空望远镜科学研究所);University of California, Berkeley(加州大学伯克利分校);Johns Hopkins University(约翰斯·霍普金斯大学);Rutgers the State University of New Jersey(新泽西州立罗格斯大学);ASI-Space Science Data Center(意大利航天局空间科学数据中心);University of Edinburgh(爱丁堡大学)
Jack T. Warfield, Kevin A. McKinnon, Sangmo Tony Sohn, Nitya Kallivayalil, Alessandro Savino, Roeland P. van der Marel, Andrew B. Pace, Christopher T. Garling, … 展开作者

Jack T. Warfield, Kevin A. McKinnon, Sangmo Tony Sohn, Nitya Kallivayalil, Alessandro Savino, Roeland P. van der Marel, Andrew B. Pace, Christopher T. Garling, Niusha Ahvazi, Paul Bennet, Roger E. Cohen, Matteo Correnti, Mark A. Fardal, Kristen B. W. McQuinn, Max J. B. Newman, Eduardo Vitral

AI总结:

本研究利用HST/ACS两历元7年基线的观测数据,采用三类不同参考系测量超暗矮星系天龙座II的自行,证实纳入背景星系可将测量精度提升最高约2倍,得到了目前精度最高的该星系系统自行测量值。

摘要:

我们给出了银河系超暗矮卫星星系天龙座II(Draco II)的自行(PM)测量结果。这些自行数据是利用哈勃空间望远镜高级巡天相机(HST/ACS)的两个观测历元成像测量得到的,观测时间基线跨度为7年。低光度系统的自行测量难度较大,因为其成员星数量少,需要高精度的惯性参考系。我们使用三类不同的外源构建参考系:1)具有Gaia DR3数据的恒星,2)静止背景星系,3)前两者的组合。我们证实三种参考系给出的自行结果一致。研究发现,在这种恒星稀疏的低光度场景下,与仅使用Gaia天体测量数据相比,将背景星系纳入参考系可使测量精度提升最高约2倍。以301个背景星系作为参考系,我们测得天龙座II的系统自行值为$(μ_α^*, μ_δ) = (1.043\boldsymbol{\u00b1}0.029, 0.879\boldsymbol{\u00b1}0.028)$ mas/yr,这是本文给出的三类测量中精度最高的结果。

英文摘要:

We present proper motion (PM) measurements for Draco II, an ultra-faint dwarf satellite of the Milky Way. These PMs are measured using two epochs of Hubble Space Telescope Advanced Camera for Surveys (HST/ACS) imaging separated by a 7 year time baseline. Measuring PMs of low-luminosity systems is difficult due to the low number of member stars, requiring a precise inertial reference frame. We construct reference frames using three different sets of external sources: 1) stars with Gaia DR3 data, 2) stationary background galaxies, and 3) a combination of the two. We show that all three reference frames give consistent PM results. We find that for this sparse, low-luminosity regime including background galaxies into the reference frame improves our measurement by up to $\sim2\times$ versus using only Gaia astrometric data. Using 301 background galaxies as a reference frame, we find that Draco II's systemic PM is $(μ_α^*, μ_δ) = (1.043\pm0.029, 0.879\pm0.028)$ mas/yr, which is the most precise measurement of the three we present in this paper.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑