arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2510.22301cs.LGcs.AI
收藏

AnyECG-Lab:基于单导联心电图信号微调心电图基础模型以估计实验室值的探索性研究

AnyECG-Lab: An Exploration Study of Fine-tuning an ECG Foundation Model to Estimate Laboratory Values from Single-Lead ECG Signals

Institute of Medical Technology, Peking University Health Science Center(北京大学人民医院医学技术研究所);National Institute of Health Data Science, Peking University(北京大学国家健康数据科学研究院);School of Intelligence Science and Technology, Peking University(北京大学智能科学与技术学院);HeartVoice Medical Technology(心声医疗技术);Department of Cardiology, Peking University People’s Hospital(北京大学人民医院心内科);Institute for Artificial Intelligence, Peking University(北京大学人工智能研究院);State Key Laboratory of Vascular Homeostasis and Remodeling, NHC Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Peking University(国家心血管病分子生物学与调节肽重点实验室,北京大学)

Yujie Xiao, Gongzhen Tang, Wenhui Liu, Jun Li, Guangkun Nie, Zhuoran Kan, Deyun Zhang, Qinghao Zhao, Shenda Hong

AI总结:

本研究通过迁移学习微调ECGFounder基础模型,在斯坦福MC-MED数据集上利用单导联心电图估计实验室值,验证了非侵入性实时检测的可行性。

摘要:

及时获取实验室检查值对于临床决策至关重要,然而目前的方法依赖于侵入性的静脉采血,且本质上存在时间延迟。心电图(ECG)作为一种非侵入性且广泛可用的信号,为快速实验室估计提供了一种有前景的模态。近期深度学习的进展使得从心电图中提取潜在的血液学特征成为可能。然而,现有模型受限于低信噪比、显著的个体间变异性、有限的数据多样性以及欠佳的泛化能力,尤其是在适应低导联可穿戴设备时。在本研究中,我们开展了一项探索性研究,利用迁移学习在斯坦福大学的急诊科多模态临床监测(MC-MED)数据集上微调ECGFounder——一个大规模预训练的心电图基础模型。我们生成了超过2000万个标准化十秒心电图片段的语料库,以增强对细微生化相关性的敏感性。在内部验证中,该模型对三十三项实验室指标表现出较强的预测性能(曲线下面积高于0.65),对五十九项指标表现出中等性能(介于0.55和0.65之间),对十六项指标表现出有限性能(低于0.55)。本研究提供了一种高效的人工智能驱动解决方案,并确立了实时、非侵入性估计实验室值的可行性范围。

英文摘要:

Timely access to laboratory values is critical for clinical decision-making, yet current approaches rely on invasive venous sampling and are intrinsically delayed. Electrocardiography (ECG), as a non-invasive and widely available signal, offers a promising modality for rapid laboratory estimation. Recent progress in deep learning has enabled the extraction of latent hematological signatures from ECGs. However, existing models are constrained by low signal-to-noise ratios, substantial inter-individual variability, limited data diversity, and suboptimal generalization, especially when adapted to low-lead wearable devices. In this work, we conduct an exploratory study leveraging transfer learning to fine-tune ECGFounder, a large-scale pre-trained ECG foundation model, on the Multimodal Clinical Monitoring in the Emergency Department (MC-MED) dataset from Stanford. We generated a corpus of more than 20 million standardized ten-second ECG segments to enhance sensitivity to subtle biochemical correlates. On internal validation, the model demonstrated strong predictive performance (area under the curve above 0.65) for thirty-three laboratory indicators, moderate performance (between 0.55 and 0.65) for fifty-nine indicators, and limited performance (below 0.55) for sixteen indicators. This study provides an efficient artificial-intelligence driven solution and establishes the feasibility scope for real-time, non-invasive estimation of laboratory values.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑