arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2510.22073cs.CV

基于SSIM引导解缠的扫描仪无关MRI谐波化

Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement

MOX, Department of Mathematics Politecnico di Milano(MOX数学系,米兰理工大学)

Luca Caldera, Lara Cavinato, Francesca Ieva

AI总结:

提出SSIM引导解缠的MRI谐波化框架,分离解剖与扫描仪变异,提升跨站点一致性,脑龄误差降2.06年,AD分类AUC升至0.85。

摘要:

MRI扫描仪型号、采集协议和成像部位的差异所引入的变异性,阻碍了多中心研究中一致的分析和泛化能力。我们提出了一种新颖的基于图像的谐波化框架,用于3D T1加权脑部MRI,该框架将解剖内容与扫描仪和部位特异性变异进行解缠。模型整合了基于结构相似性指数(SSIM)的可微损失,以在减少部位间变异性的同时保留生物学上有意义的特征。该损失能够分别评估图像亮度、对比度和结构成分。训练和验证在多个公开可用的数据集上进行,涵盖不同的扫描仪和部位,并在健康人群和临床人群上进行了测试。使用多个风格目标(包括风格无关的参考)进行谐波化,产生了一致且高质量的输出。视觉比较、体素强度分布和基于SSIM的指标表明,谐波化后的图像在跨采集设置中实现了强对齐,同时保持了解剖保真度。谐波化后,结构SSIM达到0.97,亮度SSIM范围在0.98至0.99之间,平均体素强度分布之间的Wasserstein距离显著减小。下游任务显示出显著改进:脑龄预测的平均绝对误差从5.36年降至3.30年,阿尔茨海默病分类的AUC从0.78提升至0.85。总体而言,我们的框架增强了跨部位图像一致性,保持了解剖保真度,并提高了下游模型性能,为大规模多中心神经影像研究提供了稳健且可泛化的解决方案。

英文摘要:

The variability introduced by differences in MRI scanner models, acquisition protocols, and imaging sites hinders consistent analysis and generalizability across multicenter studies. We present a novel image-based harmonization framework for 3D T1-weighted brain MRI, which disentangles anatomical content from scanner- and site-specific variations. The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features while reducing inter-site variability. This loss enables separate evaluation of image luminance, contrast, and structural components. Training and validation were performed on multiple publicly available datasets spanning diverse scanners and sites, with testing on both healthy and clinical populations. Harmonization using multiple style targets, including style-agnostic references, produced consistent and high-quality outputs. Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings while maintaining anatomical fidelity. Following harmonization, structural SSIM reached 0.97, luminance SSIM ranged from 0.98 to 0.99, and Wasserstein distances between mean voxel intensity distributions decreased substantially. Downstream tasks showed substantial improvements: mean absolute error for brain age prediction decreased from 5.36 to 3.30 years, and Alzheimer's disease classification AUC increased from 0.78 to 0.85. Overall, our framework enhances cross-site image consistency, preserves anatomical fidelity, and improves downstream model performance, providing a robust and generalizable solution for large-scale multicenter neuroimaging studies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑