摘要:
本文分析了巴马科当地市场上不同来源(即不同批次)的58片500mg商用对乙酰氨基酚片剂的近红外(NIR)光谱。光谱采集的波长范围为930nm-1700nm。样品被分为48个样品组成的标定集(训练集)与10个样品组成的验证集(测试集)。为开展多变量标定,我们将三种非线性回归技术——高斯过程回归(Gaussian processes regression, GPR)、随机森林(Random Forest, RF)、支持向量机(Support vector machine, KSVM),与传统的线性偏最小二乘回归(partial least-squares regression, PLSR)结合,应用于58个样品的多种数据预处理结果。结果显示,就RMSE(均方根误差)而言,三种非线性回归标定方法的预测性能均优于PLS。为确定最优回归模型,我们未采用R²,因为该指标不适用于此场景,转而以RMSE作为不同多变量模型的比较依据。此外,为评估数据预处理的影响,我们将上述回归技术分别应用于原始数据、多元散射校正(Multi-scattering correction, MSC)、标准变量归一化(standard variate normalization, SNV)校正、平滑校正、一阶导数(first derivative, FD)与二阶导数(second derivative, SD)校正数据。整体结果表明,经平滑校正后应用高斯过程回归(GPR)可得到最低的验证(预测)均方根误差RMSEP=2.303053e-06,以及最低的标定均方根误差RMSEC=2.112316e-06。研究还发现,无论采用何种数据预处理方式,所构建的GPR模型均具备更高的准确性与更优的表现。
英文摘要:
In this article, we analyze the near-infrared (NIR) spectra of fifty-eight (58) commercial tablets of 500 mg of paracetamol from different origins (that is, with different batch numbers) in the local markets in Bamako. The NIR spectra were recorded in the spectral range 930 nm-1700 nm. The samples are divided into forty-eight (48) samples forming the set of calibration (training set) and ten (10) samples used as the validation or test set. To perform multivariate calibration, we apply-three nonlinear regression techniques (Gaussian processes regression (GPR), Random Forest (RF), Support vector machine (KSVM)), along with the traditional linear partial least-squares regression (PLSR) to several data pretreatments of the 58 samples. The results show that the three nonlinear regression calibrations have better prediction performance than PLS as far as RMSE is concerned. To decide the best regression model, we avoid R2 since this quantity is not a good parameter for this purpose. We will instead consider RMSE when comparing the different multivariate models. Additionally, to assess the impact of data preprocessing, we apply the above regression techniques to the original data, Multi-scattering correction (MSC), standard variate normalization (SNV) correction, smoothing correction, first derivative (FD), and second derivative correction (SD). The overall results reveal that Gaussian Processes Regression (GPR) applied to smooth correction gives the lowest RMSEP = 2.303053e-06 for validation (prediction) and RMSEC = 2.112316e-06 for calibration. In our investigation, one also notices that the developed GPR model is more accurate and exhibits enhanced behavior no matter which data preprocessing is used.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。