arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2509.03313physics.med-ph
收藏

基于gMicroMC的蒙特卡罗模拟研究进展:反应性物种积累促进Flash剂量率下的自由基-自由基反应

Advancements in Monte Carlo simulations with gMicroMC: reactive species build-up promotes radical-radical reactions at Flash dose rates

Miguel Molina-Hernandez, Patricia Gonçalves, Yujie Chi, Joao Seco

AI总结:

本研究扩展了基于GPU的蒙特卡罗算法gMicroMC以支持多脉冲与Flash剂量率模拟,发现超高剂量率下反应性物种积累会增强自由基-自由基反应,为化学剂量率依赖研究提供了新工具。

摘要:

对水进行超高剂量率辐照的实验显示,自由基-自由基反应存在增强效应,这一现象可能与Flash效应相关。本研究的目的是对gMicroMC进行扩展,使其支持多脉冲模拟和Flash剂量率条件,并在纯水模型中探究Flash条件下自由基-自由基反应增强的潜在机制。gMicroMC是一种基于GPU的蒙特卡罗径迹结构算法,本研究对其进行了功能扩展以实现多脉冲模拟。研究中采用多个70 MeV质子脉冲辐照纯水,总剂量最高可达20 Gy;脉冲剂量率设置为2×10^5 Gy/s和10^6 Gy/s,平均剂量率的范围为0.01至100000 Gy/s。研究以H2O2的G值作为指标,监测剂量率对自由基-自由基反应的影响。扩展后的多脉冲版本gMicroMC已通过与Kinetiscope的对比完成验证。多脉冲模拟结果表明存在一个平均剂量率阈值:当剂量率低于该阈值时,自由基会在脉冲间隔内完全消耗,因此G值保持恒定;当剂量率高于该阈值时,反应性物种会在整个辐照过程中持续积累,导致自由基-自由基反应增多,进而使H2O2的G值升高。对于脉冲剂量率为2×10^5 Gy/s和10^6 Gy/s的情况,平均剂量率阈值分别约为10 Gy/s和100 Gy/s量级。在超高剂量率条件下,脉冲间的短暂间隔会引发反应性物种的积累,从而增强自由基-自由基反应;与径迹间机制相比,这种积累效应更易促进自由基-自由基反应的发生。gMicroMC的此次功能升级为研究化学剂量率依赖关系提供了一种先进的工具。

英文摘要:

Ultra-high dose rate irradiations to water indicate an enhancement of radical-radical reactions, which could potentially correlate with the Flash effect. The purpose of this work was to extend gMicroMC to support multiple pulse simulations and Flash dose rates, and to investigate, in a pure water model, the mechanisms underlying the enhancement of radical-radical reactions under Flash conditions. gMicroMC, a GPU-based Monte Carlo track-structure algorithm, was extended to simulate multiple pulses. Pure water was exposed to multiple 70 MeV protons pulses delivering up to 20 Gy. The pulse dose rate was set to 2*10^5 and 10^6 Gy/s, while the average dose rate ranged from 0.01 to 100000 Gy/s. The G-values of H2O2 were used to monitor the influence of dose rate on radical-radical reactions. The multiple pulse extension of gMicroMC was validated against Kinetiscope. Multiple pulse simulations indicated an average dose rate threshold. Below it, complete radical depletion occurred within the pulses, leading to constant G-values. Above it, reactive species accumulated throughout the irradiation, resulting in an increase of radical-radical reactions and thus the G-values of H2O2. The average dose rate thresholds were in the order of 10 and 100 Gy/s for pulse dose rates of 2*10^5 and 10^6 Gy/s, respectively. At ultra-high dose rates, the brief intervals between pulses led to a reactive species build-up, which enhanced radical-radical reactions. This build-up is more likely to promote radical-radical reactions than the inter-track mechanism. The advancements in gMicroMC provide a sophisticated tool to study chemical dose rate dependencies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑