基于仿真的心电图中健康与患病心脏激活与复极序列的数字孪生
Simulation-based digital twinning of activation and repolarisation sequences from the ECG across healthy and diseased hearts
AI总结:
提出一种基于仿真的数字孪生方法,通过12导联ECG和心室解剖重建,利用迭代优化准确推断健康及患病心脏的心室激活与复极时间。
摘要:
心室复极的异常模式会导致多种心脏疾病中的致命性心律失常,包括遗传性和获得性通道病、心肌病以及缺血性心脏病。然而,检测这些复极异常的方法十分有限。在本研究中,我们提出并评估了一种新颖的基于仿真的方法,该方法通过12导联心电图(ECG)和磁共振衍生的心室解剖重建来推断心室激活和复极时间,首次适用于健康对照者和复极异常病例。首先,通过迭代优化早期激活位点和传导速度,直到模型与目标QRS波群匹配,重建心室激活时间。然后,通过迭代优化心室动作电位时程和动作电位形状参数,直到模型与目标T波匹配(包含正则化),重建心室复极时间。复极推断在18个已知复极时间的基准仿真上进行了评估,包括对照和伴有复极异常的肥厚型心肌病(HCM)病例。推断的复极时间在对照和HCM中与真实值显示出良好的一致性(Spearman r分别为0.63+/-0.11和0.65+/-0.19),推断的模型T波与目标T波紧密匹配(r分别为0.81+/-0.05和0.78+/-0.08)。该方法进一步展示了在一系列异常心室复极序列中重建宏观延迟复极模式的灵活性,证明了对多种病理病例的适用性。基于仿真的推断能够在正常和异常复极模式病例中,从12导联ECG准确重建复极时间。
英文摘要:
Abnormal patterns of ventricular repolarisation contribute to lethal arrhythmias in various cardiac conditions, including inherited and acquired channelopathies, cardiomyopathies, and ischaemic heart disease. However, methods to detect these repolarisation abnormalities are limited. In this study, we introduce and assess a novel simulation-based method to infer ventricular activation and repolarisation times from the 12-lead electrocardiogram (ECG) and magnetic resonance-derived ventricular anatomical reconstruction, applicable for the first time to both healthy controls and cases with abnormal repolarisation. First, ventricular activation times were reconstructed through iterative refinement of early activation sites and conduction velocities, until the model and target QRS complexes matched. Then, ventricular repolarisation times were reconstructed through iterative refinement of ventricular action potential durations and an action potential shape parameter until the model and target T waves matched, including regularisation. Repolarisation inference was evaluated against 18 benchmark simulations with known repolarisation times, including both control and hypertrophic cardiomyopathy (HCM) cases with abnormal repolarisation. Inferred repolarisation times showed good agreement with the ground truth in control and HCM (Spearman r=0.63+/-0.11 and 0.65+/-0.19, respectively), with inferred model T waves closely matching the target T waves (r=0.81+/-0.05 and 0.78+/-0.08, respectively). The method further demonstrated flexibility in reconstructing the macroscopic patterns of delayed repolarisation across a range of abnormal ventricular repolarisation sequences, demonstrating applicability to a range of pathological cases. Simulation-based inference can accurately reconstruct repolarisation times from the 12-lead ECG in cases with both normal and abnormal repolarisation patterns.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。