磁机械谐振器的固有频率对磁体距离的依赖性

Natural Frequency Dependency of Magneto-Mechanical Resonators on Magnet Distance

Jonas Faltinath, Fabian Mohn, Fynn Foerger, Martin Möddel, Tobias Knopp

AI总结:

本文研究磁机械谐振器固有频率随转子—定子磁体距离的变化,提出鲁棒的频率提取方法,并用考虑材料与制造不确定性的改进偶极子模型实现高精度建模与校准。

摘要:

在任意位置精确推导温度或压力等物理量,在医疗操作或工业过程工程等众多场景中都具有重要价值。磁机械谐振器(MMR)是一种新型传感技术,基于转子与定子永磁体之间的相互作用,能够在同时感测外部被测参量的情况下,对传感器的位置和姿态进行联合跟踪。在此过程中,该物理量与扭转振荡频率相耦合,例如通过改变磁体距离实现。本文分析了MMR传感器的固有频率对转子—定子距离的依赖性(该依赖性与偏转角无关),并评估了理论模型的性能。所提出的三种传感器采用球形和/或圆柱形几何结构的磁体,可在61.9–307.3 Hz范围内以可调频率工作。我们提出的固有频率获取方法对初始偏转振幅和品质因数的变化表现出显著鲁棒性,所得均值的统计误差小于0.05%。研究发现,距离—频率关系可由考虑材料和制造不确定性的改进偶极子模型很好地描述。通过调整单个参数即可补偿这些因素的综合影响,从而使模型偏差中位数通常低于0.2%。本文所述方法和结果对于采用MMR技术的新型传感器的设计与校准过程具有重要意义。

英文摘要:

The precise derivation of physical quantities like temperature or pressure at arbitrary locations is useful in numerous contexts, e.g. medical procedures or industrial process engineering. The novel sensor technology of magneto-mechanical resonators (MMR), based on the interaction of a rotor and stator permanent magnet, allows for the combined tracking of the sensor position and orientation while simultaneously sensing an external measurand. Thereby, the quantity is coupled to the torsional oscillation frequency, e.g. by varying the magnet distance. In this paper, we analyze the (deflection angle-independent) natural frequency dependency of MMR sensors on the rotor-stator distance, and evaluate the performance of theoretical models. The three presented sensors incorporate magnets of spherical and/or cylindrical geometry and can be operated at adjustable frequencies within the range of 61.9-307.3 Hz. Our proposed method to obtain the natural frequency demonstrates notable robustness to variations in the initial deflection amplitudes and quality factors resulting in statistical errors on the mean smaller than 0.05 %. We find that the distance-frequency relationship is well described by an adapted dipole model accounting for material and manufacturing uncertainties. Their combined effect can be compensated by an adjustment of a single parameter which drives the median model deviation generally below 0.2 %. Our depicted methods and results are important for the design and calibration process of new sensor types utilizing the MMR technique.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑