arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2502.13880eess.SYcs.SY
收藏

在可变低耦合条件下实现稳定输出的E/EF类感应电能传输

Class E/EF Inductive Power Transfer to Achieve Stable Output under Variable Low Coupling

Yifan Zhao, Mowei Lu, Heyuan Li, Zhenbin Zhang, Minfan Fu, Stefan M. Goetz

AI总结:

针对弱耦合下IPT系统输出不稳定问题,本文基于E/EF类逆变器采用扩展阻抗模型和副边失谐设计,实现低耦合变化下的稳定输出,并通过400 kHz原型验证。

摘要:

本文开发了一种基于E/EF类逆变器、具有稳定输出功率的感应电能传输(IPT)系统。E/EF类逆变器的负载无关设计近来引起了广泛关注。然而,当耦合系数较弱时,将该设计应用于IPT系统已被证明具有挑战性。为解决这一问题,本文采用扩展阻抗模型,并用失谐设计替代副边的完全谐振。因此,即使在低耦合系数下,系统也能保持稳定输出。一个400 kHz的实验原型验证了这些发现。实验结果表明,当耦合系数在0.04至0.07之间变化时,输出功率波动保持在15%以内,峰值功率效率达到91%。

英文摘要:

This paper develops an inductive power transfer(IPT)system with stable output power based on a Class E/EF inverter. Load-independent design of Class E/EF inverter has recently attracted widespread interest. However, applying this design to IPT systems has proven challenging when the coupling coefficient is weak. To solve this issue, this paper uses an expanded impedance model and substitutes the secondary side's perfect resonance with a detuned design. Therefore, the system can maintain stable output even under a low coupling coefficient. A 400 kHz experimental prototype validates these findings. The experimental results indicate that the output power fluctuation remains within 15% as the coupling coefficient varies from 0.04 to 0.07. The peak power efficiency achieving 91%

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑