关于《复兴一种被忽视的气-水流动测量技术》的讨论

Discussion on "Resurrecting a Neglected Measurement Technique for Air-Water Flows"

Matthias Kramer, Hang Wang, Daniel B. Bung

AI总结:

本文针对气-水流动中掺混空气与卷入空气的区分难题,提出一种相检测探头信号判别方法,可直接从现有双探头数据中分离两类空气,替代传统浸入式探头。

摘要:

近年来,人们重新关注区分高弗劳德数自掺气水流中空气浓度的不同组成部分,例如 Kramer(2024)的研究,这些组成包括掺混空气(entrained air)和卷入空气(entrapped air)。前者以掺混空气包和气泡为特征,而卷入空气则对应沿波峰和波谷输送的空气。卷入空气最早由 Killen(1968)使用所谓的浸入式探头(dipping probe)测量,而对浸入式探头信号的物理解释直到后来才由 Wilhelms 和 Gulliver(2005)给出。自那时以来,人们普遍认为,要完全量化掺混空气和卷入空气,需要两种不同的测量仪器,例如浸入式探头和普通的相检测探头。最近,Wilhelms 和 Gulliver(2024)发表了题为《复兴一种被忽视的气-水流动测量技术》的文章,他们重申了将这些概念应用于空化预防和气-水气体传质的重要性,以及使用两种独立测量仪器的必要性。本文祝贺作者在掺混空气和卷入空气方面作出的开创性工作(Wilhelms and Gulliver 2005;Wilhelms and Gulliver 2024),并指出这些概念在过去二十年中一直被忽视。在本讨论中,提出了一种用于相检测探头信号的简单判别技术,该技术能够从使用最先进的双探头相检测探头记录的现有数据集中区分掺混空气和卷入空气。人们相信,这种新颖的信号处理方法将使 Killen(1968)的浸入式探头变得不再必要,并将有助于验证卷入空气的非侵入式测量,以及推动自掺气水流中气-水传质的基于物理模型的发展。

英文摘要:

Over the last years, there has been a renewed interest in differentiating various contributions to the air concentration in high Froude-number self-aerated flows, see for example Kramer (2024), comprising entrained and entrapped air. The former is characterized by entrained air packets and bubbles, while entrapped air corresponds to air transported along wave peaks and troughs. Entrapped air was first measured by Killen (1968) using a so-called dipping probe, while a physical interpretation of the dipping probe signals was provided only later by Wilhelms and Gulliver (2005). Since then, it has been commonly accepted that two different measurement instruments, for example a dipping probe and a common phase-detection probe, are required to fully quantify entrained and entrapped air. Recently, an article entitled "Resurrecting a Neglected Measurement Technique for Air-Water Flows" was published by Wilhelms and Gulliver (2024), who re-iterated the importance of applying these concepts for cavitation prevention and air-water gas transfer, as well as the need for two separate measurement instruments. The authors are congratulated for their seminal works on entrained and entrapped air (Wilhelms and Gulliver 2005; Wilhelms and Gulliver 2024), and it is stipulated that these concepts have been overlooked in the last two decades. In this discussion, a simple discrimination technique for phase-detection probe signals is proposed, which allows to differentiate entrained and entrapped air from existing datasets, recorded with a state-of-the-art dual-tip phase-detection probe. It is believed that this novel signal processing method will make Killen's (1968) dipping probe redundant, and that it will be useful for the validation of non-intrusive measurements of entrapped air, as well as for the development of physics-based models for air-water mass transfer in self-aerated flows.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑